Application of an imaging plate for estimating the uncertainty in direct organ measurements due to a variation of the detector placement

https://repo.qst.go.jp/records/71641
https://repo.qst.go.jp/records/71641
9dc0ad77-2ed4-4aeb-8949-992149e1f44a
Item type 会議発表用資料 / Presentation(1)
公開日 2015-04-27
タイトル
タイトル Application of an imaging plate for estimating the uncertainty in direct organ measurements due to a variation of the detector placement
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference object
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Kurihara, Osamu

× Kurihara, Osamu

WEKO 704902

Kurihara, Osamu

Search repository
K.Kanai

× K.Kanai

WEKO 704903

K.Kanai

Search repository
M.Hirota

× M.Hirota

WEKO 704904

M.Hirota

Search repository
Tani, Kotaro

× Tani, Kotaro

WEKO 704905

Tani, Kotaro

Search repository
Eunjoo, Kim

× Eunjoo, Kim

WEKO 704906

Eunjoo, Kim

Search repository
栗原 治

× 栗原 治

WEKO 704907

en 栗原 治

Search repository
谷 幸太郎

× 谷 幸太郎

WEKO 704908

en 谷 幸太郎

Search repository
金 ウンジュ

× 金 ウンジュ

WEKO 704909

en 金 ウンジュ

Search repository
抄録
内容記述タイプ Abstract
内容記述 The uncertainty of a quantified activity amount due to a variation of the detector location is one of the concerned issues in direct organ measurements. The authors proposed a new usage of an imaging plate (IP) technique for estimating this uncertainty. This method needs only to set an array of regions of interest (ROIs) on a latent image obtained from the IP; each of the ROIs corresponds to an active area of the detector to be used. This work benchmarked the method through an experiment using a realistic torso phantom containing an 241Am liver source. The latent image of the source was obtained by irradiating the IP (20 x 40 cm2) from the anterior surface of the phantom. The phantom was also measured with a HPGe detector with an active area of 70 mm in diameter. As a result, the comparison in the response between the IP and the HPGe detector was made for six of 144 circular ROIs arranged on the latent image, showing in a good correlation (r2= 0.994). This suggested that the uncertainty of concern in the present measurement with the HPGe detector was inherited from the dispersion of counts on the latent image: 8.2% of the 144 ROIs. Although a practical use of the IP in the direct organ measurements still has difficulties (e.g., a fading effect), the IP would be a useful tool not only for optimizing the detector location, but also for avoiding possible underestimations of the activity amount due to inappropriate locations of the detector by visual confirmation.
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述タイプ Other
内容記述 International Conference on Individual Monitoring of Ionising Radiation 2015(iM2015)
発表年月日
日付 2015-04-21
日付タイプ Issued
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 19:48:59.974624
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3