{"created":"2023-05-15T14:52:28.301339+00:00","id":71641,"links":{},"metadata":{"_buckets":{"deposit":"b31c11c1-e3b9-4f40-8a8f-92c43a80ea9d"},"_deposit":{"created_by":1,"id":"71641","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"71641"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00071641","sets":["10:28"]},"author_link":["704909","704902","704904","704906","704903","704905","704907","704908"],"item_10005_date_7":{"attribute_name":"発表年月日","attribute_value_mlt":[{"subitem_date_issued_datetime":"2015-04-21","subitem_date_issued_type":"Issued"}]},"item_10005_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"The uncertainty of a quantified activity amount due to a variation of the detector location is one of the concerned issues in direct organ measurements. The authors proposed a new usage of an imaging plate (IP) technique for estimating this uncertainty. This method needs only to set an array of regions of interest (ROIs) on a latent image obtained from the IP; each of the ROIs corresponds to an active area of the detector to be used. This work benchmarked the method through an experiment using a realistic torso phantom containing an 241Am liver source. The latent image of the source was obtained by irradiating the IP (20 x 40 cm2) from the anterior surface of the phantom. The phantom was also measured with a HPGe detector with an active area of 70 mm in diameter. As a result, the comparison in the response between the IP and the HPGe detector was made for six of 144 circular ROIs arranged on the latent image, showing in a good correlation (r2= 0.994). This suggested that the uncertainty of concern in the present measurement with the HPGe detector was inherited from the dispersion of counts on the latent image: 8.2% of the 144 ROIs. Although a practical use of the IP in the direct organ measurements still has difficulties (e.g., a fading effect), the IP would be a useful tool not only for optimizing the detector location, but also for avoiding possible underestimations of the activity amount due to inappropriate locations of the detector by visual confirmation. ","subitem_description_type":"Abstract"}]},"item_10005_description_6":{"attribute_name":"会議概要(会議名, 開催地, 会期, 主催者等)","attribute_value_mlt":[{"subitem_description":"International Conference on Individual Monitoring of Ionising Radiation 2015(iM2015)","subitem_description_type":"Other"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Kurihara, Osamu"}],"nameIdentifiers":[{"nameIdentifier":"704902","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"K.Kanai"}],"nameIdentifiers":[{"nameIdentifier":"704903","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"M.Hirota"}],"nameIdentifiers":[{"nameIdentifier":"704904","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Tani, Kotaro"}],"nameIdentifiers":[{"nameIdentifier":"704905","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Eunjoo, Kim"}],"nameIdentifiers":[{"nameIdentifier":"704906","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"栗原 治","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"704907","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"谷 幸太郎","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"704908","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"金 ウンジュ","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"704909","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"conference object","resourceuri":"http://purl.org/coar/resource_type/c_c94f"}]},"item_title":"Application of an imaging plate for estimating the uncertainty in direct organ measurements due to a variation of the detector placement","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Application of an imaging plate for estimating the uncertainty in direct organ measurements due to a variation of the detector placement"}]},"item_type_id":"10005","owner":"1","path":["28"],"pubdate":{"attribute_name":"公開日","attribute_value":"2015-04-27"},"publish_date":"2015-04-27","publish_status":"0","recid":"71641","relation_version_is_last":true,"title":["Application of an imaging plate for estimating the uncertainty in direct organ measurements due to a variation of the detector placement"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T19:48:59.875909+00:00"}