ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 学会発表・講演等
  2. ポスター発表

A Full-Ring Prototype PET-MRI System Based on Four-Layer DOI-PET Detectors Integrated with a RF Coil

https://repo.qst.go.jp/records/71584
https://repo.qst.go.jp/records/71584
3b104635-f080-4e52-9a59-e94aab660bbd
Item type 会議発表用資料 / Presentation(1)
公開日 2015-02-20
タイトル
タイトル A Full-Ring Prototype PET-MRI System Based on Four-Layer DOI-PET Detectors Integrated with a RF Coil
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference object
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 錦戸, 文彦

× 錦戸, 文彦

WEKO 704023

錦戸, 文彦

Search repository
清水, 浩大

× 清水, 浩大

WEKO 704024

清水, 浩大

Search repository
菅, 幹生

× 菅, 幹生

WEKO 704025

菅, 幹生

Search repository
稲玉, 直子

× 稲玉, 直子

WEKO 704026

稲玉, 直子

Search repository
吉田, 英治

× 吉田, 英治

WEKO 704027

吉田, 英治

Search repository
田島, 英朗

× 田島, 英朗

WEKO 704028

田島, 英朗

Search repository
小畠, 隆行

× 小畠, 隆行

WEKO 704029

小畠, 隆行

Search repository
山谷, 泰賀

× 山谷, 泰賀

WEKO 704030

山谷, 泰賀

Search repository
錦戸 文彦

× 錦戸 文彦

WEKO 704031

en 錦戸 文彦

Search repository
清水 浩大

× 清水 浩大

WEKO 704032

en 清水 浩大

Search repository
菅 幹生

× 菅 幹生

WEKO 704033

en 菅 幹生

Search repository
稲玉 直子

× 稲玉 直子

WEKO 704034

en 稲玉 直子

Search repository
吉田 英治

× 吉田 英治

WEKO 704035

en 吉田 英治

Search repository
田島 英朗

× 田島 英朗

WEKO 704036

en 田島 英朗

Search repository
小畠 隆行

× 小畠 隆行

WEKO 704037

en 小畠 隆行

Search repository
山谷 泰賀

× 山谷 泰賀

WEKO 704038

en 山谷 泰賀

Search repository
抄録
内容記述タイプ Abstract
内容記述 We are developing a brain-dedicated PET-MRI system in which our original, four-layer DOI-PET detectors are integrated with a birdcage RF-coil. The main development issue is making the PET ring diameter as small as possible while avoiding interference with the RF-coil, in order to realize a highly sensitive PET system with high spatial resolution by making full use of DOI measurement capabilities. In this paper, we finally developed a full-ring prototype of the proposed PET-MRI system, and we carried out simultaneous measurements with a 3.0 T MRI. The prototype system consists of eight four-layer DOI PET detectors and the birdcage RF-coil developed for the proposed system. The PET detectors consist of six monolithic multi-pixel photon counter (MPPC) arrays (S11064-050P) arranged in a row, a readout circuit, two four-layer DOI scintillator arrays and a shielding box. LYSO crystals are arranged in 19 × 6 × 4 array to form a crystal block, and each crystal block is coupled to three MPPC arrays. Each crystal element is 2.0 × 2.0 × 5.0 mm3. The diameter of the RF-coil elements is 27.5cm. There are eight coil elements in the RF-coil and the PET detectors are mounted on all gaps between the RF-coil elements. We evaluated performance of the prototype system. The PET detectors, the RF-coil and the cables were in an MRI room. A data acquisition system and power supply for the MPPCs and preamplifiers were outside the MRI room and connected to all the detectors through a penetration panel. Gradient echo (GRE) and spin echo (SE) methods were used in an evaluation experiment on the simultaneous measurements. We observed no degradation of crystal identification and energy performances. We conclude that influence of the simultaneous measurements on the PET performance is negligible.
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述タイプ Other
内容記述 2014IEEE NSS/MIC 参加・発表
発表年月日
日付 2014-11-13
日付タイプ Issued
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 19:49:37.994929
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3