WEKO3
アイテム
Performance Evaluation of a Transformable Axial-Shift Type Single-Ring OpenPET
https://repo.qst.go.jp/records/71349
https://repo.qst.go.jp/records/713497e974ff0-8821-446d-87e1-d82c4487b483
Item type | 会議発表用資料 / Presentation(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2013-11-14 | |||||
タイトル | ||||||
タイトル | Performance Evaluation of a Transformable Axial-Shift Type Single-Ring OpenPET | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_c94f | |||||
資源タイプ | conference object | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Yoshida, Eiji
× Yoshida, Eiji× Shinaji, Tetsuya× Tashima, Hideaki× Haneishi, Hideaki× Yamaya, Taiga× 吉田 英治× 品地 哲弥× 田島 英朗× 羽石 秀昭× 山谷 泰賀 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | One of the challenging applications of PET is implementing it for in-beam PET, which is an in situ monitoring method for charged particle therapy. For this purpose, we have previously proposed two geometries for our open-type PET scanners named OpenPET. The original OpenPET had a physically opened field-of-view (FOV) between two detector rings through which irradiation beams pass. This dual-ring OpenPET (DROP) had a wide axial FOV including the gap. But, this geometry is not necessarily the most efficient for application to in-beam PET in which only a limited FOV around the irradiation field is required. Therefore, we proposed a single-ring OpenPET (SROP) geometry which can provide an accessible and observable open space with higher sensitivity and a reduced number of detectors compared to DROP. Also, we proposed two arrangement types, a slanted ellipse (SE) type where oval detector rings are slanted and stacked and an axial shift (AS) type where block detectors originally forming a conventional PET scanner are axially shifted little by little. Previously, we developed the SE-SROP prototype, and showed its good performance for in-beam PET. However, the SE-SROP decreased sensitivity slightly relative to the ring-type PET and needed a large gantry in the axial direction for conventional PET studies. On the other hand, AS-SROP can transform conventional ring-type PET scanners into stacked detectors with a gradual axial shift. In this work, we developed and evaluated a small AS-SROP prototype for proof-of-concept. The AS-SROP prototype was designed with 2 cylinder-shaped detector rings of 16 DOI detectors. The system sensitivity and spatial resolution were measured and were 5.1% and 2.6 mm, respectively, for the OpenPET mode. For the conventional PET mode, the system sensitivity and spatial resolution were 7.3% and 2.2 mm, respectively. We concluded that the AS-SROP geometry has a good potential for not only in-beam imaging but also conventional PET studies. | |||||
会議概要(会議名, 開催地, 会期, 主催者等) | ||||||
内容記述タイプ | Other | |||||
内容記述 | The 2013 IEEE Nuclear Science Symposium and Medical Imaging Conference, and Room-Temperature Semiconductor X-Ray and Gamma-Ray Detectors workshop | |||||
発表年月日 | ||||||
日付 | 2013-11-02 | |||||
日付タイプ | Issued |