{"created":"2023-05-15T14:52:15.415219+00:00","id":71349,"links":{},"metadata":{"_buckets":{"deposit":"7bb2a09c-03eb-4aaf-8ff3-8cac81166e08"},"_deposit":{"created_by":1,"id":"71349","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"71349"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00071349","sets":["10:28"]},"author_link":["701565","701566","701571","701570","701572","701569","701573","701568","701567","701574"],"item_10005_date_7":{"attribute_name":"発表年月日","attribute_value_mlt":[{"subitem_date_issued_datetime":"2013-11-02","subitem_date_issued_type":"Issued"}]},"item_10005_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"One of the challenging applications of PET is implementing it for in-beam PET, which is an in situ monitoring method for charged particle therapy. For this purpose, we have previously proposed two geometries for our open-type PET scanners named OpenPET. The original OpenPET had a physically opened field-of-view (FOV) between two detector rings through which irradiation beams pass. This dual-ring OpenPET (DROP) had a wide axial FOV including the gap. But, this geometry is not necessarily the most efficient for application to in-beam PET in which only a limited FOV around the irradiation field is required. Therefore, we proposed a single-ring OpenPET (SROP) geometry which can provide an accessible and observable open space with higher sensitivity and a reduced number of detectors compared to DROP. Also, we proposed two arrangement types, a slanted ellipse (SE) type where oval detector rings are slanted and stacked and an axial shift (AS) type where block detectors originally forming a conventional PET scanner are axially shifted little by little. Previously, we developed the SE-SROP prototype, and showed its good performance for in-beam PET. However, the SE-SROP decreased sensitivity slightly relative to the ring-type PET and needed a large gantry in the axial direction for conventional PET studies. On the other hand, AS-SROP can transform conventional ring-type PET scanners into stacked detectors with a gradual axial shift. In this work, we developed and evaluated a small AS-SROP prototype for proof-of-concept. The AS-SROP prototype was designed with 2 cylinder-shaped detector rings of 16 DOI detectors. The system sensitivity and spatial resolution were measured and were 5.1% and 2.6 mm, respectively, for the OpenPET mode. For the conventional PET mode, the system sensitivity and spatial resolution were 7.3% and 2.2 mm, respectively. We concluded that the AS-SROP geometry has a good potential for not only in-beam imaging but also conventional PET studies.","subitem_description_type":"Abstract"}]},"item_10005_description_6":{"attribute_name":"会議概要(会議名, 開催地, 会期, 主催者等)","attribute_value_mlt":[{"subitem_description":"The 2013 IEEE Nuclear Science Symposium and Medical Imaging Conference, and Room-Temperature Semiconductor X-Ray and Gamma-Ray Detectors workshop","subitem_description_type":"Other"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Yoshida, Eiji"}],"nameIdentifiers":[{"nameIdentifier":"701565","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Shinaji, Tetsuya"}],"nameIdentifiers":[{"nameIdentifier":"701566","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Tashima, Hideaki"}],"nameIdentifiers":[{"nameIdentifier":"701567","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Haneishi, Hideaki"}],"nameIdentifiers":[{"nameIdentifier":"701568","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Yamaya, Taiga"}],"nameIdentifiers":[{"nameIdentifier":"701569","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"吉田 英治","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"701570","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"品地 哲弥","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"701571","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"田島 英朗","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"701572","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"羽石 秀昭","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"701573","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"山谷 泰賀","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"701574","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"conference object","resourceuri":"http://purl.org/coar/resource_type/c_c94f"}]},"item_title":"Performance Evaluation of a Transformable Axial-Shift Type Single-Ring OpenPET","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Performance Evaluation of a Transformable Axial-Shift Type Single-Ring OpenPET"}]},"item_type_id":"10005","owner":"1","path":["28"],"pubdate":{"attribute_name":"公開日","attribute_value":"2013-11-14"},"publish_date":"2013-11-14","publish_status":"0","recid":"71349","relation_version_is_last":true,"title":["Performance Evaluation of a Transformable Axial-Shift Type Single-Ring OpenPET"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T19:52:17.274168+00:00"}