ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 学会発表・講演等
  2. ポスター発表

Carbon ion radiotherapy for skull base and paracervical chordomas

https://repo.qst.go.jp/records/71000
https://repo.qst.go.jp/records/71000
d5a0d41b-6cdd-4e64-b794-20b5a64eb7c4
Item type 会議発表用資料 / Presentation(1)
公開日 2012-11-30
タイトル
タイトル Carbon ion radiotherapy for skull base and paracervical chordomas
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference object
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Koto, Masashi

× Koto, Masashi

WEKO 697853

Koto, Masashi

Search repository
Hasegawa, Azusa

× Hasegawa, Azusa

WEKO 697854

Hasegawa, Azusa

Search repository
Takagi, Ryo

× Takagi, Ryo

WEKO 697855

Takagi, Ryo

Search repository
Sasahara, Go

× Sasahara, Go

WEKO 697856

Sasahara, Go

Search repository
Ikawa, Hiroaki

× Ikawa, Hiroaki

WEKO 697857

Ikawa, Hiroaki

Search repository
Kamada, Tadashi

× Kamada, Tadashi

WEKO 697858

Kamada, Tadashi

Search repository
Iwadate, Yasuo

× Iwadate, Yasuo

WEKO 697859

Iwadate, Yasuo

Search repository
Matsutani, Masao

× Matsutani, Masao

WEKO 697860

Matsutani, Masao

Search repository
小藤 昌志

× 小藤 昌志

WEKO 697861

en 小藤 昌志

Search repository
長谷川 安都佐

× 長谷川 安都佐

WEKO 697862

en 長谷川 安都佐

Search repository
高木 亮

× 高木 亮

WEKO 697863

en 高木 亮

Search repository
佐々原 剛

× 佐々原 剛

WEKO 697864

en 佐々原 剛

Search repository
伊川 裕明

× 伊川 裕明

WEKO 697865

en 伊川 裕明

Search repository
鎌田 正

× 鎌田 正

WEKO 697866

en 鎌田 正

Search repository
岩立 康男

× 岩立 康男

WEKO 697867

en 岩立 康男

Search repository
松谷 雅生

× 松谷 雅生

WEKO 697868

en 松谷 雅生

Search repository
抄録
内容記述タイプ Abstract
内容記述 High linear energy transfer charged particles such as carbon ions have excellent dose localizing properties, and this can cause excellent local control while minimizing the effect on normal tissues. Between April 1997 and January 2012, 50 patients with skull base and paracervical chordomas were treated with carbon ion radiotherapy at National Institute of Radiological Sciences in Japan. In this study, we investigated the toxicity and efficacy of carbon ion radiotherapy for skull base and paracervical chordomas. The 50 patients consisted of 23 males and 27 females. Their ages ranged from 16 to 76 years, with a median of 55 years. Thirty-four tumors located in the skull base region and 16 in the paracervical region. The planning target volume ranged from 11 to 481 ml, with a median of 84 ml. The patients were treated with a median dose of 60.8 GyE (range; 48-60.8 GyE) in 16 fractions over 4 weeks. Acute toxicity was assessed based on the RTOG score, and late toxicity was determined based on the RTOG/ EORTC score. Local control was defined as showing no evidence of tumor regrowth in the irradiated volume. The follow-up periods ranged from 4 to 163 months, with a median of 54 months. There was no evidence of any serious acute reactions (Grade ≥4). Regarding late reactions, two patients decreased visual acuity and 2 developed mucosal ulcerations in the irradiated volume. The 5-year local and loco-regional control rates were 88.6% and 78.7%, respectively. The 5-year overall survival and progression free survival rates were 88.2% and 68.7%, respectively. The 5-year local control and overall survival rates for 40 patients treated with a dose of 60.8 GyE were 92.7% and 88.4%, respectively. Carbon ion radiotherapy with a dose of 60.8 GyE in 16 fractions was safe and effective for skull base and paracervical chordomas.
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述タイプ Other
内容記述 17th Annual Scientific Meeting and Education Day of the Society for Neuro-Oncology
発表年月日
日付 2012-11-18
日付タイプ Issued
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 19:56:21.413691
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3