ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 学会発表・講演等
  2. ポスター発表

Comparison of SUVmax and SUVpeak measuring FDG uptake for robust predictions of patient prognosis of pancreas cancer treated by carbon ion radiotherapy

https://repo.qst.go.jp/records/70976
https://repo.qst.go.jp/records/70976
4bdbece8-5faa-44ca-a277-ccb2cc8f7e54
Item type 会議発表用資料 / Presentation(1)
公開日 2012-11-12
タイトル
タイトル Comparison of SUVmax and SUVpeak measuring FDG uptake for robust predictions of patient prognosis of pancreas cancer treated by carbon ion radiotherapy
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference object
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Yoshikawa, Kyosan

× Yoshikawa, Kyosan

WEKO 697593

Yoshikawa, Kyosan

Search repository
Ohashi, Seiya

× Ohashi, Seiya

WEKO 697594

Ohashi, Seiya

Search repository
Toubaru, Sachiko

× Toubaru, Sachiko

WEKO 697595

Toubaru, Sachiko

Search repository
Hasebe, Mitsuhiko

× Hasebe, Mitsuhiko

WEKO 697596

Hasebe, Mitsuhiko

Search repository
Tamura, Katsumi

× Tamura, Katsumi

WEKO 697597

Tamura, Katsumi

Search repository
Shiraishi, Takahiro

× Shiraishi, Takahiro

WEKO 697598

Shiraishi, Takahiro

Search repository
Tanimoto, Katsuyuki

× Tanimoto, Katsuyuki

WEKO 697599

Tanimoto, Katsuyuki

Search repository
Yamada, Shigeru

× Yamada, Shigeru

WEKO 697600

Yamada, Shigeru

Search repository
Kandatsu, Susumu

× Kandatsu, Susumu

WEKO 697601

Kandatsu, Susumu

Search repository
Fukumura, Toshimitsu

× Fukumura, Toshimitsu

WEKO 697602

Fukumura, Toshimitsu

Search repository
Saga, Tsuneo

× Saga, Tsuneo

WEKO 697603

Saga, Tsuneo

Search repository
Kamada, Tadashi

× Kamada, Tadashi

WEKO 697604

Kamada, Tadashi

Search repository
吉川 京燦

× 吉川 京燦

WEKO 697605

en 吉川 京燦

Search repository
大橋 靖也

× 大橋 靖也

WEKO 697606

en 大橋 靖也

Search repository
桃原 幸子

× 桃原 幸子

WEKO 697607

en 桃原 幸子

Search repository
長谷部 充彦

× 長谷部 充彦

WEKO 697608

en 長谷部 充彦

Search repository
田村 克巳

× 田村 克巳

WEKO 697609

en 田村 克巳

Search repository
白石 貴博

× 白石 貴博

WEKO 697610

en 白石 貴博

Search repository
谷本 克之

× 谷本 克之

WEKO 697611

en 谷本 克之

Search repository
山田 滋

× 山田 滋

WEKO 697612

en 山田 滋

Search repository
神立 進

× 神立 進

WEKO 697613

en 神立 進

Search repository
福村 利光

× 福村 利光

WEKO 697614

en 福村 利光

Search repository
佐賀 恒夫

× 佐賀 恒夫

WEKO 697615

en 佐賀 恒夫

Search repository
鎌田 正

× 鎌田 正

WEKO 697616

en 鎌田 正

Search repository
抄録
内容記述タイプ Abstract
内容記述 Purpose: Various parameters are used for measuring tumor glucose metabolic activity with 18F-FDG PET
including measuring the single maximum pixel value within the slice with highest radioactivity concentration
(SUVmax) or placing a fixed ROI in the area of the tumor with the highest level of 18F-FDG uptake (SUVpeak),
which it defines as the largest possible mean value of a 1 cm3 spherical VOI positioned within a tumor. SUVmax
is avoided inter-observer variation, but a major drawback of this approach is its susceptibility to noise in the
data. SUVpeak is also removed inter-observer variation, and the averaging of multiple voxels reduces the
susceptibility to noise. In this study we determined which parameter of glucose metabolic activity provided the
most robust predictions of patient prognosis of pancreas cancer treated by carbon ion radiotherapy.
Materials and Methods: A total of 41 patients (28 males, 13 females; mean age, 65 + 8+- y) with pancreas cancer
underwent 18F-FDG PET/CT scan before carbon ion radiotherapy. The following parameters on the
pretreatment scans were measured: maximum standardized uptake value (SUVmax), two types of peak SUV
(small: SUVpeak5, large: SUVpeak10), and average SUV (SUVave). SUVpeak5 and SUVpeak10 are measured
using spherical VOI with radius 5 mm and 10 mm, respectively. SUVave is an average pixel value of the circular
ROI with radius 5 mm within the slice with the highest radioactivity concentration. Correlation coefficients were
calculated for these parameters, and receiver operating characteristic (ROC) analysis was performed to
compare the prediction performance of each parameter for pancreas patients.
Results: Pretreatment SUVmax, SUVpeak5, SUVpeak10, and SUVave averaged 6.6, 6.1, 5.1, and 6.0,
respectively. Correlation coefficients between all four parameters, SUVmax and SUVpeak5, SUVmax and
SUVpeak10, SUVmax and SUVave, SUVpeak5 and SUVpeak10, SUVpeak5 and SUVave, SUVpeak10 and
SUVave, were 0.995, 0.964, 0.994, 0.973, 0.995, and 0.969, respectively. The areas under the ROC curve of
SUVmax, SUVpeak5, SUVpeak10, and SUVave were 0.69, 0.69, 0.92, and 0.70, respectively. ROC curves of
SUVmax, SUVpeak5 and SUVave were closely approximated to each other, but the ROC curve of SUVpeak10
was different from others and much better than others.
Conclusions: Four FDG-PET uptake parameters were correlated closely. ROC analysis showed that
SUVpeak10 was much better than others for prediction of pancreas patient prognosis. It seemed that relatively
large sphere for calculating SUVpeak is better than small sphere if the tumor is large enough for setting the
sphere within it.
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述タイプ Other
内容記述 Annual Congress of the European Association of Nuclear Medicine
発表年月日
日付 2012-10-31
日付タイプ Issued
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 19:56:38.181381
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3