Role of FDG-PET as a predictor of distant failure in preoperative Carbon-ion radiotherapy for pancreatic cancer

https://repo.qst.go.jp/records/70750
https://repo.qst.go.jp/records/70750
a131b139-f143-4b2a-a17a-438d29068ac9
Item type 会議発表用資料 / Presentation(1)
公開日 2012-05-21
タイトル
タイトル Role of FDG-PET as a predictor of distant failure in preoperative Carbon-ion radiotherapy for pancreatic cancer
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference object
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Shinoto, Makoto

× Shinoto, Makoto

WEKO 695006

Shinoto, Makoto

Search repository
Yamada, Shigeru

× Yamada, Shigeru

WEKO 695007

Yamada, Shigeru

Search repository
Yoshikawa, Kyosan

× Yoshikawa, Kyosan

WEKO 695008

Yoshikawa, Kyosan

Search repository
Yasuda, Shigeo

× Yasuda, Shigeo

WEKO 695009

Yasuda, Shigeo

Search repository
Imada, Hiroshi

× Imada, Hiroshi

WEKO 695010

Imada, Hiroshi

Search repository
Kamada, Tadashi

× Kamada, Tadashi

WEKO 695011

Kamada, Tadashi

Search repository
篠藤 誠

× 篠藤 誠

WEKO 695012

en 篠藤 誠

Search repository
山田 滋

× 山田 滋

WEKO 695013

en 山田 滋

Search repository
吉川 京燦

× 吉川 京燦

WEKO 695014

en 吉川 京燦

Search repository
安田 茂雄

× 安田 茂雄

WEKO 695015

en 安田 茂雄

Search repository
今田 浩史

× 今田 浩史

WEKO 695016

en 今田 浩史

Search repository
鎌田 正

× 鎌田 正

WEKO 695017

en 鎌田 正

Search repository
抄録
内容記述タイプ Abstract
内容記述 Purpose/Objective
The aim of this study was to evaluate the role of positron emission tomography using 18F-fluorodeoxyglucose (FDG-PET) in the indication of preoperative carbon ion radiotherapy for the patients with resectable pancreatic cancer.
Materials and Methods
The patients with resectable pancreatic cancer underwent preoperative short course carbon ion radiotherapy (CIRT) in our institution. On the PET-CT before CIRT, the tumor was contoured and the maximum standardized uptake value (SUVmax) was calculated. The SUVmax was compared between two groups, patients with and without distant recurrence after CIRT. The low-SUVmax and the high-SUVmax subgroups were created by categorizing patients above or below the median SUVmax. The impact of the SUVmax on the prognosis for patients was assessed by analyzing the correlations between the SUVmax and the distant metastasis free survival (DMFS) and overall survival (OS). In addition, the analysis was performed by following factors; age, carbohydrate antigen 19-9, tumor volume, and clinical stage.
Results
Twenty-one patients were included in this study. Sixteen of 21 patients underwent surgery. For the entire population, local recurrence was observed in no patient and distant metastasis in 13 patients (62%). The median SUVmax was 4.3 (range, 2.2-8.2). DMFS of the low-SUVmax group and the high- SUVmax group were 91% and 20% for 1 year and 71% and 0% for 3 year, respectively (p<0.0001). OS of the low-SUVmax group and the high-SUVmax group were 91% and50% for 1 year and 81% and 0% for 3 year, respectively (p<0.0001). An SUVmax >4.3 was the only risk factor for distant recurrence in the univariate analysis.
Conclusions
Our data indicated statistically significant correlation between SUVmax and DMFS. FDG-PET is considered to be useful to determine the indication of preoperative short course CIRT for the patients with resectable pancreatic cancer.
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述タイプ Other
内容記述 ESTRO 31
発表年月日
日付 2012-05-13
日付タイプ Issued
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 19:59:16.132415
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3