ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 学会発表・講演等
  2. ポスター発表

Potential of hair root cells for dose estimation in partial body exposure

https://repo.qst.go.jp/records/70055
https://repo.qst.go.jp/records/70055
2a5440ca-5ecf-4d5f-8c10-974c98593d85
Item type 会議発表用資料 / Presentation(1)
公開日 2010-03-15
タイトル
タイトル Potential of hair root cells for dose estimation in partial body exposure
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference object
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Takashima, Yoshio

× Takashima, Yoshio

WEKO 687889

Takashima, Yoshio

Search repository
Nakata, Akifumi

× Nakata, Akifumi

WEKO 687890

Nakata, Akifumi

Search repository
Takada, Misaki

× Takada, Misaki

WEKO 687891

Takada, Misaki

Search repository
Akiyma, Miho

× Akiyma, Miho

WEKO 687892

Akiyma, Miho

Search repository
Yoshida, Mitsuaki

× Yoshida, Mitsuaki

WEKO 687893

Yoshida, Mitsuaki

Search repository
高島 良生

× 高島 良生

WEKO 687894

en 高島 良生

Search repository
中田 章史

× 中田 章史

WEKO 687895

en 中田 章史

Search repository
川崎 実佐紀

× 川崎 実佐紀

WEKO 687896

en 川崎 実佐紀

Search repository
穐山 美穂

× 穐山 美穂

WEKO 687897

en 穐山 美穂

Search repository
吉田 光明

× 吉田 光明

WEKO 687898

en 吉田 光明

Search repository
抄録
内容記述タイプ Abstract
内容記述 Accidental radiation exposure should be estimated as accurately as practicable. This aids physicians in deciding the appropriate medical procedures. Chromosomal aberrations in the peripheral lymphocytes are the most reliable indicators for biological dose estimation. The conventional method for estimating this dose uses score marker aberrations, such as dicentric and ring chromosomes in lymphocytes. However, because lymphocytes circulate in the peripheral blood, the dose estimated from these dicentric or ring values is the mean dose of whole-body cumulative radiation exposure. Therefore, in the case of partial body exposure, it is difficult to estimate the partial dose of radiation by this method. It is necessary to use the partial organ in order to estimate the dose of partial body exposure. The aim of this study is to establish an assay system to evaluate the dose of partial body exposure. For this purpose, we used the human hair root as the target organ and detected the indicators of dose estimation; further, we examined the method of culturing hair root cells for detecting chromosomal aberrations. The epilated hairs were dissected carefully, and single cells were isolated enzymatically. When the hair was irradiated with gamma radiation, DNA damage was detectable in the comet assay, and the cultured hair root cells were grown in vitro. These results suggest that dose estimation of partial body exposure is possible using hair root cells.
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述タイプ Other
内容記述 BioDose 2008
発表年月日
日付 2008-09-10
日付タイプ Issued
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 20:07:21.935226
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3