ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 学会発表・講演等
  2. ポスター発表

Application of NOBIAS CHELATE resin for thorium separation from seawater

https://repo.qst.go.jp/records/69940
https://repo.qst.go.jp/records/69940
f9b302d3-4418-46b4-b611-e8266ffedc57
Item type 会議発表用資料 / Presentation(1)
公開日 2009-11-13
タイトル
タイトル Application of NOBIAS CHELATE resin for thorium separation from seawater
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference object
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Takata, Hyoe

× Takata, Hyoe

WEKO 686733

Takata, Hyoe

Search repository
Zheng, Jian

× Zheng, Jian

WEKO 686734

Zheng, Jian

Search repository
Tagami, Keiko

× Tagami, Keiko

WEKO 686735

Tagami, Keiko

Search repository
Aono, Tatsuo

× Aono, Tatsuo

WEKO 686736

Aono, Tatsuo

Search repository
Uchida, Shigeo

× Uchida, Shigeo

WEKO 686737

Uchida, Shigeo

Search repository
高田 兵衛

× 高田 兵衛

WEKO 686738

en 高田 兵衛

Search repository
鄭 建

× 鄭 建

WEKO 686739

en 鄭 建

Search repository
田上 恵子

× 田上 恵子

WEKO 686740

en 田上 恵子

Search repository
青野 辰雄

× 青野 辰雄

WEKO 686741

en 青野 辰雄

Search repository
内田 滋夫

× 内田 滋夫

WEKO 686742

en 内田 滋夫

Search repository
抄録
内容記述タイプ Abstract
内容記述 Since thorium (Th) concentration in seawater is extremely low (ca. 1.0 ng/L), elimination of matrix elements and concentration of Th is necessary for its measurement. A NOBIAS CHELATE resin was evaluated for its ability of Th separation and preconcentration from water samples. We measured concentrations of Th in the eluted samples by inductively coupled plasma mass spectrometry (Yokogawa, Agilent 7500c). The NOBIAS CHELATE resin could completely recover Th at a pH range of 2-5 from Th spiked purified water samples. Then we used spiked seawater samples after adjusting their pH to 2.5 with hydrochloric acid; More than 95% recovery of Th was observed. Total procedural blank for Th was 0.02 ng/L using 50 mL of purified water (10-fold preconcentration, n = 3). The detection limits, defined as 3 times the standard deviation for the procedural blank, was 0.06 ng/L. Thus Th in seawater samples could be measured by the proposed method.
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述タイプ Other
内容記述 International Workshop on Low-level Measurement of Radionuclides and Its Application to Earth and Environmental Sciences
発表年月日
日付 2009-11-06
日付タイプ Issued
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 20:08:40.054327
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3