ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 学会発表・講演等
  2. ポスター発表

Simplified Quantification of Adenosine A2A Receptor with [11C]TMSX PET and Graphical Analyses

https://repo.qst.go.jp/records/69797
https://repo.qst.go.jp/records/69797
97b7e12b-2d2b-4a41-a8b7-3fea32cec984
Item type 会議発表用資料 / Presentation(1)
公開日 2009-07-13
タイトル
タイトル Simplified Quantification of Adenosine A2A Receptor with [11C]TMSX PET and Graphical Analyses
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference object
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Naganawa, Mika

× Naganawa, Mika

WEKO 685292

Naganawa, Mika

Search repository
Mishina, Masahiro

× Mishina, Masahiro

WEKO 685293

Mishina, Masahiro

Search repository
Sakata, Muneyuki

× Sakata, Muneyuki

WEKO 685294

Sakata, Muneyuki

Search repository
Oda, Keiichi

× Oda, Keiichi

WEKO 685295

Oda, Keiichi

Search repository
Ishii, Kenji

× Ishii, Kenji

WEKO 685296

Ishii, Kenji

Search repository
Ishiwata, Kiichi

× Ishiwata, Kiichi

WEKO 685297

Ishiwata, Kiichi

Search repository
Kimura, Yuichi

× Kimura, Yuichi

WEKO 685298

Kimura, Yuichi

Search repository
長縄 美香

× 長縄 美香

WEKO 685299

en 長縄 美香

Search repository
坂田 宗之

× 坂田 宗之

WEKO 685300

en 坂田 宗之

Search repository
織田 圭一

× 織田 圭一

WEKO 685301

en 織田 圭一

Search repository
石井 賢二

× 石井 賢二

WEKO 685302

en 石井 賢二

Search repository
石渡 喜一

× 石渡 喜一

WEKO 685303

en 石渡 喜一

Search repository
木村 裕一

× 木村 裕一

WEKO 685304

en 木村 裕一

Search repository
抄録
内容記述タイプ Abstract
内容記述 Objectives: [11C]TMSX is one of the few available radioligands to quantify adenosine A2A receptor (A2AR) [1]. Although A2ARs are rich in the basal ganglia and poor in other regions, [11C]TMSX binds to not only classical A2ARs but also atypical sites. Therefore, it is difficult to find a reference region. In previous studies with arterial input function, we selected the centrum semiovale (CSO) as a reference region [2,3]. The purpose of this study was to investigate the availability of graphical analyses for human [11C]TMSX studies with region of interest (ROI) analysis.
\nMethods: Seven healthy subjects were included in this study. The average dose was 570 +- 86 MBq and the specific activity was 39 +- 21 GBq/µmol. Dynamic PET scans were acquired for 1 hour with a SET-2400W (Shimadzu, Japan). A total of 25 ROIs was manually delineated on the summed PET image: CSO (reference), anterior and posterior putamen, caudate, midbrain, posterior cingulate, cerebral cortical areas, and cerebellum. The regional time-activity curves (TACs) were analyzed using one- and two-tissue compartment models (1T, 2T), Logan graphical analysis (LGA) and multilinear analysis (MA1) with a metabolite-corrected input function. TACs were also analyzed using reference Logan graphical analysis (LGAR). The clearance rate constant of the reference region (k2') for LGAR was fixed to be 0.12 min-1, the mean value from the 1T model. For all graphical methods, t* was set to be 20 min post-injection.
\nResults: Metabolism of [11C]TMSX was very slow with parent fraction of 0.98 +- 0.01 at 3 min and 0.92 +- 0.05 at 60 min. The ROIs were well described by 2T model with a constraint of VND from the 1T estimation of CSO. The values of VT ranged from 0.58 +- 0.16 (CSO) to 1.25 +- 0.29 mL/cm3 (anterior putamen), with K1 values of 0.068 +- 0.014 to 0.30 +- 0.07 mL/min/cm3. The estimated VT of graphical analyses and 2T matched well (VT(LGA) = 0.99 VT(2T) + 0.01 (r2 = 0.99), VT(MA1) = 1.01 VT(2T) + 0.01 (r2 = 0.99)). The estimated VT in CSO was 5% higher in graphical analyses than in 1T model. As a result, the estimated BPND of LGA and MA1 showed smaller values compared with compartment model analysis (BPND(2T) = 0.83BPND(MA1) + 0.06 (r2 = 0.92)). The LGAR provided similar results (BPND(LGAR) = 0.99BPND(MA1) - 0.01 (r2 = 0.99)).
\nConclusions: All graphical analyses provided similar estimates of VT and BPND for ROI curves. This study suggests that LGAR is available for quantification of [11C]TMSX ROI analysis. The difference of BPND values in graphical analyses and compartment analysis is due to the estimates of VND value. The suitability of CSO as a reference region should be further investigated and the noise-reduction method is required for LGAR imaging.
\nReferences:
[1] Ishiwata K, et al. JNM, 41:345-354, 2000.
[2] Naganawa M, et al. EJNM, 34:679-687, 2007.
[3] Svenningsson P, et al. Synapse, 27:322-335, 1997.
Acknowledgments: This work was funded by Grants-in-Aid for Scientific Research (B) No. 16390348, (C) No. 17590901 and No. 20591033 from JSPS.
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述タイプ Other
内容記述 Brain'09 & BrainPET'09
発表年月日
日付 2009-07-03
日付タイプ Issued
戻る
0
views
See details
Views