ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 学会発表・講演等
  2. ポスター発表

Diffusion-weighted fMRI signal in rat somatosensory cortex at 7T

https://repo.qst.go.jp/records/69465
https://repo.qst.go.jp/records/69465
f9b4c987-d784-4b0b-925a-fccb2209c168
Item type 会議発表用資料 / Presentation(1)
公開日 2008-09-24
タイトル
タイトル Diffusion-weighted fMRI signal in rat somatosensory cortex at 7T
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference object
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Kershaw, Jeffrey

× Kershaw, Jeffrey

WEKO 681727

Kershaw, Jeffrey

Search repository
Obata, Takayuki

× Obata, Takayuki

WEKO 681728

Obata, Takayuki

Search repository
Joonas, Autio

× Joonas, Autio

WEKO 681729

Joonas, Autio

Search repository
Shibata, Sayaka

× Shibata, Sayaka

WEKO 681730

Shibata, Sayaka

Search repository
Kuroiwa, Daigo

× Kuroiwa, Daigo

WEKO 681731

Kuroiwa, Daigo

Search repository
Kanno, Iwao

× Kanno, Iwao

WEKO 681732

Kanno, Iwao

Search repository
Aoki, Ichio

× Aoki, Ichio

WEKO 681733

Aoki, Ichio

Search repository
Kershaw Jeffrey

× Kershaw Jeffrey

WEKO 681734

en Kershaw Jeffrey

Search repository
小畠 隆行

× 小畠 隆行

WEKO 681735

en 小畠 隆行

Search repository
ヨーナス オーティオ

× ヨーナス オーティオ

WEKO 681736

en ヨーナス オーティオ

Search repository
柴田 さやか

× 柴田 さやか

WEKO 681737

en 柴田 さやか

Search repository
黒岩 大悟

× 黒岩 大悟

WEKO 681738

en 黒岩 大悟

Search repository
菅野 巖

× 菅野 巖

WEKO 681739

en 菅野 巖

Search repository
青木 伊知男

× 青木 伊知男

WEKO 681740

en 青木 伊知男

Search repository
抄録
内容記述タイプ Abstract
内容記述 Diffusion-weighted fMRI has attracted some as a technique that might provide information more directly correlated with actual neural activity than BOLD fMRI.A number of interpretations have been proposed for the diffusion-weighted signal,however many questions remain unanswered.To further examine the dependence of fMRI on b-value,somatosensory forepaw stimulation was conducted on alpha-chloralose anesthetised rats at 7 T.Functional images were acquired at five b-values(b=0,200.800.1400and2000s/mm2)and two echo-times(TE=30and60ms). The mean signal changes from all rats showed a clear difference in signal amplitude between data acquired at differentTEs, although the response shape is qualitatively similar.In contrast to previous human data,the positive stimulus-correlated signal change and post-stimulus undershoot showed a slight downward (but insignificant)
trend with increased b-value.Note that the undershoot persists for higher b-values.
The IV contribution to the TE=60 ms data may be substantially attenuated because of the relatively short T2 of blood at7T.
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述タイプ Other
内容記述 第36回日本磁気共鳴医学会
発表年月日
日付 2008-09-11
日付タイプ Issued
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 20:14:10.279458
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3