Biological studies using human cell lines and the current status of the microbeam irradiation system, SPICE

https://repo.qst.go.jp/records/69009
https://repo.qst.go.jp/records/69009
9f4a2bc1-1c78-4924-842d-7841daf5f366
Item type 会議発表用資料 / Presentation(1)
公開日 2007-07-17
タイトル
タイトル Biological studies using human cell lines and the current status of the microbeam irradiation system, SPICE
言語
言語 jpn
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference object
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 小西, 輝昭

× 小西, 輝昭

WEKO 677263

小西, 輝昭

Search repository
石川, 剛弘

× 石川, 剛弘

WEKO 677264

石川, 剛弘

Search repository
磯, 浩之

× 磯, 浩之

WEKO 677265

磯, 浩之

Search repository
安田, 仲宏

× 安田, 仲宏

WEKO 677266

安田, 仲宏

Search repository
大熊, 俊介

× 大熊, 俊介

WEKO 677267

大熊, 俊介

Search repository
児玉, 久美子

× 児玉, 久美子

WEKO 677268

児玉, 久美子

Search repository
濱野, 毅

× 濱野, 毅

WEKO 677269

濱野, 毅

Search repository
酢屋, 徳啓

× 酢屋, 徳啓

WEKO 677270

酢屋, 徳啓

Search repository
今関, 等

× 今関, 等

WEKO 677271

今関, 等

Search repository
小西 輝昭

× 小西 輝昭

WEKO 677272

en 小西 輝昭

Search repository
石川 剛弘

× 石川 剛弘

WEKO 677273

en 石川 剛弘

Search repository
安田 仲宏

× 安田 仲宏

WEKO 677274

en 安田 仲宏

Search repository
大熊 俊介

× 大熊 俊介

WEKO 677275

en 大熊 俊介

Search repository
児玉 久美子

× 児玉 久美子

WEKO 677276

en 児玉 久美子

Search repository
濱野 毅

× 濱野 毅

WEKO 677277

en 濱野 毅

Search repository
酢屋 徳啓

× 酢屋 徳啓

WEKO 677278

en 酢屋 徳啓

Search repository
今関 等

× 今関 等

WEKO 677279

en 今関 等

Search repository
抄録
内容記述タイプ Abstract
内容記述 A microbeam irradiation system, SPICE(Single Particle Irradiation system to Cell), is under completion at the National Institute of Radiological Sciences (NIRS). We have improved the beam size, which is now approximately 10um diameter, and the cell targeting system, which can irradiated maximum of 1.0x105 cells per hour. The cell dish was specially designed and the cells were cultured on Si3N4 plate (3mmx3mm area with 1um thickness) consisting of 7.5mmx7.5mm frame of 200um thickness. The cell dish is set on the voice coil stage equipped on the cell targeting system, which also consist of a fluorescent microscope and a CCD camera for capturing the cell image. This microscope system captures all the image of dyed cell nuclei in a 3x3mm area and computes the coordinated of the cell position according to the fluorescence and synchronizes this with a single particle irradiation system consisting of a scintillation counter and a beam deflector for irradiation. All the procedures can automatically be performed after setting some parameters, such as a preset number of protons. SPICE is still under reliability assessment. The first experiment performed was a visualization of phosphorylated histone protein, gamma-H2AX, which is known as a marker for DNA double strand breaks using immuno-staining technique, to confirm whether the targeted cell was accurately irradiated. Now we are focusing on low dose effects and how to obtain survival curves to measure hyper-radio sensitivity by irradiating human normal fibroblast and DNA double strand break repair deficient cell lines. We have also performed an experiment to cross-check our survival curves with those obtained using other irradiation techniques, such as broad-beam irradiation. Preliminary results will be presented.
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述タイプ Other
内容記述 13th International Congress of Radiation Research
発表年月日
日付 2007-07-13
日付タイプ Issued
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 20:19:34.064272
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3