ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 学会発表・講演等
  2. 口頭発表

Quantitative Radiation Dose Assessment in Helical Four-Dimensional CT forThoracic and Abdominal Radiotherapy

https://repo.qst.go.jp/records/64336
https://repo.qst.go.jp/records/64336
636ab042-a6ed-4c3c-b250-6ff19d25e2a8
Item type 会議発表用資料 / Presentation(1)
公開日 2011-10-04
タイトル
タイトル Quantitative Radiation Dose Assessment in Helical Four-Dimensional CT forThoracic and Abdominal Radiotherapy
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference object
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Matsuzaki, Yuka

× Matsuzaki, Yuka

WEKO 634330

Matsuzaki, Yuka

Search repository
Fujii, Keisuke

× Fujii, Keisuke

WEKO 634331

Fujii, Keisuke

Search repository
Tsuruoka, Ichirou

× Tsuruoka, Ichirou

WEKO 634332

Tsuruoka, Ichirou

Search repository
Kumagai, Motoki

× Kumagai, Motoki

WEKO 634333

Kumagai, Motoki

Search repository
Mori, Shinichiro

× Mori, Shinichiro

WEKO 634334

Mori, Shinichiro

Search repository
松崎 有華

× 松崎 有華

WEKO 634335

en 松崎 有華

Search repository
藤井 啓輔

× 藤井 啓輔

WEKO 634336

en 藤井 啓輔

Search repository
鶴岡 伊知郎

× 鶴岡 伊知郎

WEKO 634337

en 鶴岡 伊知郎

Search repository
熊谷 始紀

× 熊谷 始紀

WEKO 634338

en 熊谷 始紀

Search repository
森 慎一郎

× 森 慎一郎

WEKO 634339

en 森 慎一郎

Search repository
抄録
内容記述タイプ Abstract
内容記述 Current radiotherapy including photon and particle beams gives prescribed dose preciously, however, intrafractional
organ motion is still basic problem in thoracic and abdominal treatment. To solve this, the advantage of 4DCT to
quantify organ motion is beyond the conventional 3DCT ability. As a result, local control probability could be
improved. The patient will get a significantly inferior treatment with greater complications without 4DCT for tumor
localization, albeit that, it is important to clarify the radiation dose from 4DCT. Here we quantified the radiation dose
using the anthropomorphic phantom in helical 4DCT scan. TLDs are inserted into the phantom anatomical positions.
For thoracic and abdomen scan, the effective doses were 33.1 mSv and 27.5 mSv, respectively. The phantom received a
few mSv of the X-ray scattering over the scan region, head and upper lobe of the lung as an example. The exposure
dose from 4DCT scan is a little bit higher than that from multi-phase contrast
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述タイプ Other
内容記述 The 6th Japan-Korea Joint Meeting on Medical Physics and The 11th Asia Oceania Congress of Medical Physics
発表年月日
日付 2011-10-01
日付タイプ Issued
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 21:12:46.325066
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3