{"created":"2023-05-15T14:46:53.716111+00:00","id":64336,"links":{},"metadata":{"_buckets":{"deposit":"e978c3c7-16d2-4875-ba3e-93347a0e0294"},"_deposit":{"created_by":1,"id":"64336","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"64336"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00064336","sets":["10:29"]},"author_link":["634332","634338","634337","634335","634330","634336","634331","634334","634333","634339"],"item_10005_date_7":{"attribute_name":"発表年月日","attribute_value_mlt":[{"subitem_date_issued_datetime":"2011-10-01","subitem_date_issued_type":"Issued"}]},"item_10005_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"Current radiotherapy including photon and particle beams gives prescribed dose preciously, however, intrafractional\norgan motion is still basic problem in thoracic and abdominal treatment. To solve this, the advantage of 4DCT to\nquantify organ motion is beyond the conventional 3DCT ability. As a result, local control probability could be\nimproved. The patient will get a significantly inferior treatment with greater complications without 4DCT for tumor\nlocalization, albeit that, it is important to clarify the radiation dose from 4DCT. Here we quantified the radiation dose\nusing the anthropomorphic phantom in helical 4DCT scan. TLDs are inserted into the phantom anatomical positions.\nFor thoracic and abdomen scan, the effective doses were 33.1 mSv and 27.5 mSv, respectively. The phantom received a\nfew mSv of the X-ray scattering over the scan region, head and upper lobe of the lung as an example. The exposure\ndose from 4DCT scan is a little bit higher than that from multi-phase contrast","subitem_description_type":"Abstract"}]},"item_10005_description_6":{"attribute_name":"会議概要(会議名, 開催地, 会期, 主催者等)","attribute_value_mlt":[{"subitem_description":"The 6th Japan-Korea Joint Meeting on Medical Physics and The 11th Asia Oceania Congress of Medical Physics","subitem_description_type":"Other"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Matsuzaki, Yuka"}],"nameIdentifiers":[{"nameIdentifier":"634330","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Fujii, Keisuke"}],"nameIdentifiers":[{"nameIdentifier":"634331","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Tsuruoka, Ichirou"}],"nameIdentifiers":[{"nameIdentifier":"634332","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Kumagai, Motoki"}],"nameIdentifiers":[{"nameIdentifier":"634333","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Mori, Shinichiro"}],"nameIdentifiers":[{"nameIdentifier":"634334","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"松崎 有華","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"634335","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"藤井 啓輔","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"634336","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"鶴岡 伊知郎","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"634337","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"熊谷 始紀","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"634338","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"森 慎一郎","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"634339","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"conference object","resourceuri":"http://purl.org/coar/resource_type/c_c94f"}]},"item_title":"Quantitative Radiation Dose Assessment in Helical Four-Dimensional CT forThoracic and Abdominal Radiotherapy","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Quantitative Radiation Dose Assessment in Helical Four-Dimensional CT forThoracic and Abdominal Radiotherapy"}]},"item_type_id":"10005","owner":"1","path":["29"],"pubdate":{"attribute_name":"公開日","attribute_value":"2011-10-04"},"publish_date":"2011-10-04","publish_status":"0","recid":"64336","relation_version_is_last":true,"title":["Quantitative Radiation Dose Assessment in Helical Four-Dimensional CT forThoracic and Abdominal Radiotherapy"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T21:12:46.218752+00:00"}