WEKO3
-
RootNode
アイテム
子宮頸癌における重粒子線治療前後のMethionine-PETと62CuATSM-PET診断の比較研究
https://repo.qst.go.jp/records/63253
https://repo.qst.go.jp/records/63253c1e1005c-41a5-4cbd-ac87-b7987a225451
Item type | 会議発表用資料 / Presentation(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2009-09-30 | |||||
タイトル | ||||||
タイトル | 子宮頸癌における重粒子線治療前後のMethionine-PETと62CuATSM-PET診断の比較研究 | |||||
言語 | ||||||
言語 | jpn | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_c94f | |||||
資源タイプ | conference object | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
長谷部, 充彦
× 長谷部, 充彦× 吉川, 京燦× 大橋, 靖也× 石川, 博之× 佐合, 賢治× 田巻, 倫明× 加藤, 真吾× 古川, 高子× 福村, 利光× 神立, 進× 鈴木, 和年× 佐賀, 恒夫× 辻井, 博彦× 長谷部 充彦× 吉川 京燦× 大橋 靖也× 石川 博之× 田巻 倫明× 加藤 眞吾× 古川 高子× 福村 利光× 神立 進× 鈴木 和年× 佐賀 恒夫× 辻井 博彦 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Poupose: To determine if Cu-62 labeled diacetyl-bis (N (4)-methylthiosemicarbazone); (Cu-62-ATSM) imaging of tumor hypoxia is associated with C-11-methionine(MET) imaging of amino acid metabolism in cervical cancer. \nMethod: PET/CT was performed in ten patients with cervical cancer for evaluation of both tumor hypoxia using Cu-62-ATSM and amino acid metabolism using MET. Histologically confirmed eight squamous cell carcinoma, four adenocarcima, two adenosquamous carcinoma and melanoma were enrolled in this study. Distribution of Cu-62-ATSM in tumor was compared with that of MET. The two-group system was evaluated the distribution of uptake as Matched (mostly matched with each other) and Mismatched (with each other). Tumor uptake of each tracer was also analyzed semi-quantitatively by Tumor-to-Normal-Tissue-Ratio (TNR). \nResult: Matched and Mismatched-groups were 1 case (6.7%) and 14 cases (93.3%), respectively. In Mismatched-group, Cu-62-ATSM tend to accumulate around the distal margin of high MET uptake area in the tumor. Mean TNR was 9.5 in MET and 4.0 in Cu-62-ATSM, and thus image contrast between tumor and surrounding normal tissue was higher in MET PET/CT image than Cu-62-ATSM PET/CT image. \nConclusion: Cu-62-ATSM and MET showed different distribution in most cases of cervical cancer. Cervical cancer had a greater tendency for the uptake of MET than Cu-62-ATSM. |
|||||
会議概要(会議名, 開催地, 会期, 主催者等) | ||||||
内容記述タイプ | Other | |||||
内容記述 | H20年度HIMAC共同利用研究成果発表会 | |||||
発表年月日 | ||||||
日付 | 2009-04-14 | |||||
日付タイプ | Issued |
Share
Cite as
長谷部, 充彦, 吉川, 京燦, 大橋, 靖也, 石川, 博之, 佐合, 賢治, 田巻, 倫明, 加藤, 真吾, 古川, 高子, 福村, 利光, 神立, 進, 鈴木, 和年, 佐賀, 恒夫, 辻井, 博彦, 長谷部 充彦, 吉川 京燦, 大橋 靖也, 石川 博之, 田巻 倫明, 加藤 眞吾, 古川 高子, 福村 利光, 神立 進, 鈴木 和年, 佐賀 恒夫, 辻井 博彦, 2009, 子宮頸癌における重粒子線治療前後のMethionine-PETと62CuATSM-PET診断の比較研究.
Loading...