Comparative Study Between Glass Dosimeter and Thermoluminescent Dosimeter for Postal Dose Audit System

https://repo.qst.go.jp/records/61739
https://repo.qst.go.jp/records/61739
ba0e42dc-7aa9-42c6-bce5-caf445274891
Item type 会議発表用資料 / Presentation(1)
公開日 2006-09-05
タイトル
タイトル Comparative Study Between Glass Dosimeter and Thermoluminescent Dosimeter for Postal Dose Audit System
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference object
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Mizuno, Hideyuki

× Mizuno, Hideyuki

WEKO 611145

Mizuno, Hideyuki

Search repository
Kanai, Tatsuaki

× Kanai, Tatsuaki

WEKO 611146

Kanai, Tatsuaki

Search repository
Kusano, Yohsuke

× Kusano, Yohsuke

WEKO 611147

Kusano, Yohsuke

Search repository
Ko, Susumu

× Ko, Susumu

WEKO 611148

Ko, Susumu

Search repository
Ohno, Mari

× Ohno, Mari

WEKO 611149

Ohno, Mari

Search repository
Nishizawa, Kanae

× Nishizawa, Kanae

WEKO 611150

Nishizawa, Kanae

Search repository
水野 秀之

× 水野 秀之

WEKO 611151

en 水野 秀之

Search repository
金井 達明

× 金井 達明

WEKO 611152

en 金井 達明

Search repository
幸 進

× 幸 進

WEKO 611153

en 幸 進

Search repository
大野 真里

× 大野 真里

WEKO 611154

en 大野 真里

Search repository
西澤 かな枝

× 西澤 かな枝

WEKO 611155

en 西澤 かな枝

Search repository
抄録
内容記述タイプ Abstract
内容記述 Thermoluminescent dosimeter (TLD) has been used for postal dose audit by IAEA, ESTRO and RPC. TLD is small enough to handle easily and have fine accuracy up to these days. However, the accuracy of radiotherapy has become more and more progressed and the requirement of quality assurance is increasing. We'd like to suggest glass dosimeter (GDR) for postal dose audit tool.
GDR (Chiyoda technol Co.) is radiation-induced photoluminescence (RPL) detector. RPL origins are created by irradiation and these origins are excited by UV-ray results in orange RPL emission. This RPL emission is proportional to the amount of irradiation dose. The advantages of GDR compared with TLD are repeatable readout results in reduction of random error and little fading results in reduction of systematic error.
Feasibility study using GRD were done at NIRS using linac (6MV and 10MV) and Co-60 machines. The standard deviation was about 1.2 %(N=180) which seems pretty well than conventional TLD method. We are going to confirm the accuracy of TLD using same measurement condition to make sure the GRD is the superior tool for postal dose audit.
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述タイプ Other
内容記述 World Congress on Medical Physics and Biomedical Engineering 2006
発表年月日
日付 2006-09-01
日付タイプ Issued
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 21:38:53.167863
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3