{"created":"2023-05-15T14:45:10.744496+00:00","id":61739,"links":{},"metadata":{"_buckets":{"deposit":"0e50cf07-66db-455a-9591-443b55110e77"},"_deposit":{"created_by":1,"id":"61739","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"61739"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00061739","sets":["10:29"]},"author_link":["611154","611147","611146","611151","611153","611148","611149","611145","611150","611152","611155"],"item_10005_date_7":{"attribute_name":"発表年月日","attribute_value_mlt":[{"subitem_date_issued_datetime":"2006-09-01","subitem_date_issued_type":"Issued"}]},"item_10005_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"Thermoluminescent dosimeter (TLD) has been used for postal dose audit by IAEA, ESTRO and RPC. TLD is small enough to handle easily and have fine accuracy up to these days. However, the accuracy of radiotherapy has become more and more progressed and the requirement of quality assurance is increasing. We'd like to suggest glass dosimeter (GDR) for postal dose audit tool. \nGDR (Chiyoda technol Co.) is radiation-induced photoluminescence (RPL) detector. RPL origins are created by irradiation and these origins are excited by UV-ray results in orange RPL emission. This RPL emission is proportional to the amount of irradiation dose. The advantages of GDR compared with TLD are repeatable readout results in reduction of random error and little fading results in reduction of systematic error. \nFeasibility study using GRD were done at NIRS using linac (6MV and 10MV) and Co-60 machines. The standard deviation was about 1.2 %(N=180) which seems pretty well than conventional TLD method. We are going to confirm the accuracy of TLD using same measurement condition to make sure the GRD is the superior tool for postal dose audit.","subitem_description_type":"Abstract"}]},"item_10005_description_6":{"attribute_name":"会議概要(会議名, 開催地, 会期, 主催者等)","attribute_value_mlt":[{"subitem_description":"World Congress on Medical Physics and Biomedical Engineering 2006","subitem_description_type":"Other"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Mizuno, Hideyuki"}],"nameIdentifiers":[{"nameIdentifier":"611145","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Kanai, Tatsuaki"}],"nameIdentifiers":[{"nameIdentifier":"611146","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Kusano, Yohsuke"}],"nameIdentifiers":[{"nameIdentifier":"611147","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Ko, Susumu"}],"nameIdentifiers":[{"nameIdentifier":"611148","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Ohno, Mari"}],"nameIdentifiers":[{"nameIdentifier":"611149","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Nishizawa, Kanae"}],"nameIdentifiers":[{"nameIdentifier":"611150","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"水野 秀之","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"611151","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"金井 達明","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"611152","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"幸 進","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"611153","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"大野 真里","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"611154","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"西澤 かな枝","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"611155","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"conference object","resourceuri":"http://purl.org/coar/resource_type/c_c94f"}]},"item_title":"Comparative Study Between Glass Dosimeter and Thermoluminescent Dosimeter for Postal Dose Audit System","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Comparative Study Between Glass Dosimeter and Thermoluminescent Dosimeter for Postal Dose Audit System"}]},"item_type_id":"10005","owner":"1","path":["29"],"pubdate":{"attribute_name":"公開日","attribute_value":"2006-09-05"},"publish_date":"2006-09-05","publish_status":"0","recid":"61739","relation_version_is_last":true,"title":["Comparative Study Between Glass Dosimeter and Thermoluminescent Dosimeter for Postal Dose Audit System"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T21:38:53.064478+00:00"}