ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 学会発表・講演等
  2. 口頭発表

Noninvasive Detection of Tissue Remodeling After Acute Myocardial Infarction in Rats by Radiolabeled Anti-Tenascin-C Antibody

https://repo.qst.go.jp/records/61636
https://repo.qst.go.jp/records/61636
a56f5d26-c2e2-4cc3-94a2-fede6f504c88
Item type 会議発表用資料 / Presentation(1)
公開日 2006-07-06
タイトル
タイトル Noninvasive Detection of Tissue Remodeling After Acute Myocardial Infarction in Rats by Radiolabeled Anti-Tenascin-C Antibody
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference object
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Odaka, Kenichi

× Odaka, Kenichi

WEKO 610273

Odaka, Kenichi

Search repository
Uehara, Tomoya

× Uehara, Tomoya

WEKO 610274

Uehara, Tomoya

Search repository
Arano, Yasushi

× Arano, Yasushi

WEKO 610275

Arano, Yasushi

Search repository
Adachi, Seika

× Adachi, Seika

WEKO 610276

Adachi, Seika

Search repository
Tadokoro, Hiroyuki

× Tadokoro, Hiroyuki

WEKO 610277

Tadokoro, Hiroyuki

Search repository
Hasegawa, Hiroshi

× Hasegawa, Hiroshi

WEKO 610278

Hasegawa, Hiroshi

Search repository
Yoshida, Kyoko

× Yoshida, Kyoko

WEKO 610279

Yoshida, Kyoko

Search repository
Yoshida, Toshimichi

× Yoshida, Toshimichi

WEKO 610280

Yoshida, Toshimichi

Search repository
Hiroe, Michiaki

× Hiroe, Michiaki

WEKO 610281

Hiroe, Michiaki

Search repository
Irie, Toshiaki

× Irie, Toshiaki

WEKO 610282

Irie, Toshiaki

Search repository
Tanada, Shuji

× Tanada, Shuji

WEKO 610283

Tanada, Shuji

Search repository
Yoshida, Katsuya

× Yoshida, Katsuya

WEKO 610284

Yoshida, Katsuya

Search repository
小高 謙一

× 小高 謙一

WEKO 610285

en 小高 謙一

Search repository
上原 知也

× 上原 知也

WEKO 610286

en 上原 知也

Search repository
荒野 泰

× 荒野 泰

WEKO 610287

en 荒野 泰

Search repository
足立 清夏

× 足立 清夏

WEKO 610288

en 足立 清夏

Search repository
田所 裕之

× 田所 裕之

WEKO 610289

en 田所 裕之

Search repository
長谷川 洋

× 長谷川 洋

WEKO 610290

en 長谷川 洋

Search repository
入江 俊章

× 入江 俊章

WEKO 610291

en 入江 俊章

Search repository
棚田 修二

× 棚田 修二

WEKO 610292

en 棚田 修二

Search repository
吉田 勝哉

× 吉田 勝哉

WEKO 610293

en 吉田 勝哉

Search repository
抄録
内容記述タイプ Abstract
内容記述 Background: During tissue remodeling after acute myocardial infarction (MI), tenascin-C (TNC), one of extracellular matrix glycoproteins, loosens the strong adhesion of surviving cardiomyocytes at the border zone to reorganize the cell shape or arrangement. To develop a new noninvasive diagnostic technique for the early tissue remodeling after acute MI, we tried to detect active region of tissue remodeling using radiolabeled anti-TNC antibody and single-photon emission computed tomography (SPECT). Methods: 125I anti-TNC monoclonal antibody fragment was injected intravenously to 5 acute MI rats (D) at 5 days after operation, and 5 sham-operated rats (C), and the biodistribution of this radiotracer was measured. Excised and sectioned hearts were stained with hematoxylin and eosin for histological analysis and were exposed to autoradiography. Dual-isotope SPECT imaging of 111In anti-TNC antibody and 99mTc-MIBI was also performed to examine the feasibility of this tracer for in vivo imaging. Results: Average whole heart myocardial radioactivity was significantly higher in D than C (D, 0.19+/-0.02 %injected-dose/g; C, 0.12+/-0.00; p < 0.01). Myocardial radioactivity in the infarcted area was also significantly higher in D than C (D, 0.20+/-0.02 %injected-dose/g; C, 0.11+/-0.01, p < 0.01) By autoradiography, high radioactivities were observed in the periphery of the necrotic mass in the granulation tissue. D-to-C ratio of the average autoradiographic intensity of myocardial tissue was 1.56. The ratio of autoradiographic intensities of infarcted area to noninfarcted area was 1.77. SPECT imaging demonstrated the regional myocardial uptake of 111In anti-TNC antibody, which was complementary to perfusion image. In addition, tracer distribution in the infarcted area was relatively heterogeneous. Conclusions: The present study indicated a high ability of the radiolabeled anti-TNC fragments to localize the infarcted region in the heart by ex-vivo and in-vivo imagings, suggesting its potential usefulness for the noninvasive detection of tissue remodeling.
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述タイプ Other
内容記述 Scientific Session 2003
発表年月日
日付 2003-11-12
日付タイプ Issued
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 21:40:05.054184
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3