Dose Distribution of Heavy-ion Scanning Irradiationfor Simulated for Moving Target

https://repo.qst.go.jp/records/61338
https://repo.qst.go.jp/records/61338
c653be65-5592-4d03-adf3-e4fb0190f6f4
Item type 会議発表用資料 / Presentation(1)
公開日 2006-05-04
タイトル
タイトル Dose Distribution of Heavy-ion Scanning Irradiationfor Simulated for Moving Target
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference object
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Urakabe, Eriko

× Urakabe, Eriko

WEKO 607012

Urakabe, Eriko

Search repository
Minohara, Shinichi

× Minohara, Shinichi

WEKO 607013

Minohara, Shinichi

Search repository
新谷 恵理子

× 新谷 恵理子

WEKO 607014

en 新谷 恵理子

Search repository
蓑原 伸一

× 蓑原 伸一

WEKO 607015

en 蓑原 伸一

Search repository
抄録
内容記述タイプ Abstract
内容記述 Objective:
Heavy ion radiotherapy is characterized its excellent physical dose localization and the biological
effectiveness because of its high linear energy transfer (LET). The scanning irradiation of heavy
ion, which is the highly conformal techniques, is more sensitive to motion effects. The
consequence can be under-dosage of the target volume or over-dosage of critical structures. The
effectiveness of scanning irradiation with the respiratory-gated techniques for the moving target is
evaluated in this study.
Material and Methods:
The scanning irradiation using carbon ions is planed to the target contours on a set of 3D CT
images. They are converted to the water equivalent depth coordinate and the prescribed dose is set
in and around the target region. The Bragg peaks of beams are arranged in the water equivalent
space, and the weight of each beam spot is optimized to meet the condition of the prescribed dose.
From the optimized beam arrangement and the weight, the planned dose distribution is calculated
and displayed on the axial, sagittal, or coronal multiplanar reconstruction CT image. The motion
models are constructed based on a set of sequential 3D CT volume (4D CT) data of various
clinical cases, such as lung and liver tumor. And the dose distribution simulated for the moving
target is evaluated with this model.
Results:
The scanning-irradiated dose distribution is simulated for the clinical targets based on the motion
analysis of tumor. The motion of tumor is analyzed by the direction, distance, speed and variation
of density. Especially for the heavy-ion radiotherapy, the density through beam path is crucial
because it affects strongly on the dose coverage around the distal end of the tumor. For some
clinical moving models, the dose uniformities in planning target volume and the outer dosage on
normal tissue are estimated with the timing for respiration. The quantitative analysis with the
scanning parameters such as beam size, arrangement and scanning speed, is on going.
Conclusion:
This simulation of scanning irradiation enables the clinical evaluation of the dose distribution for
the moving target. The effect on dose uniformity is estimated and the engineering requirements for
the scanning devices can be examined to the tumor on moving target.
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述タイプ Other
内容記述 Third International Conference on Translational Research and Pre-Clinical Stratgies in Radiation Oncology
発表年月日
日付 2006-03-15
日付タイプ Issued
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 21:43:33.466637
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3