WEKO3
アイテム
Localized myocardial ablation using heavy ion irradiation as a possible therapy of myocardial ischemia-induced refractory heart failure
https://repo.qst.go.jp/records/59080
https://repo.qst.go.jp/records/590803df415a8-52be-4999-b14c-c2dfb6942df3
Item type | 会議発表用資料 / Presentation(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2002-06-05 | |||||
タイトル | ||||||
タイトル | Localized myocardial ablation using heavy ion irradiation as a possible therapy of myocardial ischemia-induced refractory heart failure | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_c94f | |||||
資源タイプ | conference object | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Tanaka, Etsurou
× Tanaka, Etsurou× Yoshioka, Kouichirou× Fujikura, Hisanori× Kurosawa, Hiroyuki× Furusawa, Yoshiya× Endo, Masahiro× Tsujii, Hirohiko× 吉岡 公一郎× 藤倉 寿則× 古澤 佳也× 遠藤 真広× 辻井 博彦 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Extensive myocardial ischemia is a common cause of refractory heart failure and the degrees of ischemia is frequently inhomogenous between the regions. We propose local myocardial ablation method targeted to severe ischemic regions in order to save the remaining jeopardized regions by heavy ion beam-irradiation. Heavy ion beam being used for a less invasive cancer therapy can be localized at the target tissue in x-, y-, and z-directions with 1 mm order accuracy. Six rabbits were irradiated through the left chest (20x20 mm) by a single dose of heavy ion beam (290 MeV/u carbon-12, 92 Gy). The irradiation could be focused to the subepicardial region of the anterior left ventricle wall and did not reach to the subendocardial region. Four weeks after the irradiation, histological necrosis was confined in the outer one-third of the irradiated region. Autoradiographic analysis with 125I-metaiodobenzylguanidine revealed that transmural denervation (>85% decrease of 125I-uptake) was noted in the irradiated region but not in any other part of the heart. Contractile function evaluated by echocardiography (%FS: 27.2+5.8 vs 28.7+3.7%, n=6) and regional myocardial blood flow by microsphere method (1.76+0.56 vs 1.84+0.59 ml/min/g, n=6) were not different between the irradiated and the non-irradiated regions. General conditions and blood indices of bone marrow-, liver-, renal-functions were well maintained until sacrifice. The heavy ion beam ablation might be a possible radiotherapy for refractory heart failure resulting from an extensive myocardial ischemia, because the method allows a less invasive ablation of the severely ischemic myocardium than the conventional therapies. |
|||||
発表年月日 | ||||||
日付 | 2002-06-01 | |||||
日付タイプ | Issued |