ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. プロシーディングス

Determination of Starting Time in Logan Graphical Analysis Using the Runs Test for Quantitative PET Imaging

https://repo.qst.go.jp/records/54064
https://repo.qst.go.jp/records/54064
e1a622b5-98e8-493b-91bf-f5195d5ac199
Item type 会議発表論文 / Conference Paper(1)
公開日 2008-10-24
タイトル
タイトル Determination of Starting Time in Logan Graphical Analysis Using the Runs Test for Quantitative PET Imaging
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_5794
資源タイプ conference paper
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Kimura, Yuichi

× Kimura, Yuichi

WEKO 551884

Kimura, Yuichi

Search repository
Ogaki, Hiroto

× Ogaki, Hiroto

WEKO 551885

Ogaki, Hiroto

Search repository
Naganawa, Mika

× Naganawa, Mika

WEKO 551886

Naganawa, Mika

Search repository
Shidahara, Miho

× Shidahara, Miho

WEKO 551887

Shidahara, Miho

Search repository
Sakata, Muneyuki

× Sakata, Muneyuki

WEKO 551888

Sakata, Muneyuki

Search repository
Ishiwata, Kiichi

× Ishiwata, Kiichi

WEKO 551889

Ishiwata, Kiichi

Search repository
Suga, Mikio

× Suga, Mikio

WEKO 551890

Suga, Mikio

Search repository
木村 裕一

× 木村 裕一

WEKO 551891

en 木村 裕一

Search repository
大柿 宏人

× 大柿 宏人

WEKO 551892

en 大柿 宏人

Search repository
長縄 美香

× 長縄 美香

WEKO 551893

en 長縄 美香

Search repository
志田原 美保

× 志田原 美保

WEKO 551894

en 志田原 美保

Search repository
坂田 宗之

× 坂田 宗之

WEKO 551895

en 坂田 宗之

Search repository
石渡 喜一

× 石渡 喜一

WEKO 551896

en 石渡 喜一

Search repository
菅 幹生

× 菅 幹生

WEKO 551897

en 菅 幹生

Search repository
抄録
内容記述タイプ Abstract
内容記述 The Logan graphical analysis (LGA) is a widely used algorithm for PET quantitative
imaging. In LGA, a total distribution volume (VT) is derived as a slope in the linear relation between both radiopharmaceutical concentrations in tissues and arterial plasma after the time, t*, when the radiopharmaceutical distributes uniformly in regional tissues, and therefore t* should be specified automatically for every voxels. This study proposes a new algorithm for t* determination, ratLGA, based on the runs test, which is a nonparametric hypothesis test for randomness. In ratLGA, LGA was applied to compute residuals for the line estimation with a set of feasible t* for PET studies. Then, the runs test was employed to decide the randomness of signs in the residuals with a significance level of 0.05. ratLGA is expected to be robust against the noise observed in voxel-based tTACs. Using t* (5 to 80 [min]), ratLGA was applied to the simulated and clinical data for 11C-SA4503, which is a ligand for the sigma1 receptors (Sakata, NeuroImage, 2007). In the simulation, VT was widely ranged from 10 to 60 [mL/cm3] considering the kinetics of SA4503, and the linear regressions for estimated VT were y=0.94x-1.23 in ratLGA and
y=0.81x+3.80 when t* was fixed at 30 [min] (Sakata, 2007). The underestimation was improved by ratLGA. ratLGA increased a contrast in clinical VT images as shown in figures. Figures A and B were VT in case of ratLGA and the fixed t*, respectively, and Figure C showed the difference. In conclusion, the runs test is promising to determine t* for LGA.
書誌情報 World Molecular Imaging Congress

巻 2008, p. 0506, 発行日 2008-09
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 23:05:18.248728
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3