ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. プロシーディングス

The Chiba Clinical Experience and Current Approach for Orescribing and Reporting Ion Beam Therapy:Clinical Aspects

https://repo.qst.go.jp/records/53883
https://repo.qst.go.jp/records/53883
26267b22-7850-4c19-a3b5-60bbc800ffef
Item type 会議発表論文 / Conference Paper(1)
公開日 2007-08-29
タイトル
タイトル The Chiba Clinical Experience and Current Approach for Orescribing and Reporting Ion Beam Therapy:Clinical Aspects
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_5794
資源タイプ conference paper
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Tsujii, Hirohiko

× Tsujii, Hirohiko

WEKO 549827

Tsujii, Hirohiko

Search repository
辻井 博彦

× 辻井 博彦

WEKO 549828

en 辻井 博彦

Search repository
抄録
内容記述タイプ Abstract
内容記述 Carbon-ion therapy was begun in 1994 at the National Institute fir Radiological Sciences using HIMAC(Heavy-Ion Medical Accelerator in Chiba). Among several types of ion species, carbon ions were chosen for cancer therapy because they appeared to have the most optimal properties in terms of both biologically and physically effective dose-localization in the body. We have investigated the efficacy of carbon ions against a variety of tumours and developed effective techniques for delivering the efficient dose to the tumour. The RBE of carbon ions was estimated to be 2.0~3.0 along the spread out Bragg Peak, for acute skin reactions. As of February 2006, a total of 2,629 Patients were entered in Phase I/II or Phase II trials and were analysed for toxicity and tumour response. Tumours that appear to respond favorably to carbon ions include locally advanced tumours and those with histologically non-squamous cell type of tumours such as adenocarcinoma, adfnoid cystic carcinoma, malignant melanoma, hepatoma, and bone and soft tissue sercoma. By using biological and physical properties of carbon ion beams, the efficacy of treatment regimens with small fractions in short treatment times has been confirmed for almost all type of tumours.
書誌情報 Dose Reporting in Ion Beam Therapy (IAEA-TECDOC-1560)

巻 IAEA-TECDOC, 号 1560, p. 123-130, 発行日 2007-06
出版者
出版者 International Atomic Energy Agency
ISBN
識別子タイプ ISBN
関連識別子 978-9-2010-5807
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 23:07:25.691812
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3