ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. プロシーディングス

Development of Continuous Radon Bronchial Dosimeter

https://repo.qst.go.jp/records/53812
https://repo.qst.go.jp/records/53812
88a6cfd3-adc6-4bde-9a84-74cb4f3e6b5d
Item type 会議発表論文 / Conference Paper(1)
公開日 2007-02-27
タイトル
タイトル Development of Continuous Radon Bronchial Dosimeter
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_5794
資源タイプ conference paper
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Iwaoka, Kazuki

× Iwaoka, Kazuki

WEKO 549201

Iwaoka, Kazuki

Search repository
Tokonami, Shinji

× Tokonami, Shinji

WEKO 549202

Tokonami, Shinji

Search repository
Ishikawa, Tetsuo

× Ishikawa, Tetsuo

WEKO 549203

Ishikawa, Tetsuo

Search repository
Kobayashi, Yosuke

× Kobayashi, Yosuke

WEKO 549204

Kobayashi, Yosuke

Search repository
Takahashi, Hiroyuki

× Takahashi, Hiroyuki

WEKO 549205

Takahashi, Hiroyuki

Search repository
Yatabe, Yoshinori

× Yatabe, Yoshinori

WEKO 549206

Yatabe, Yoshinori

Search repository
Yonehara, Hidenori

× Yonehara, Hidenori

WEKO 549207

Yonehara, Hidenori

Search repository
Doi, Masahiro

× Doi, Masahiro

WEKO 549208

Doi, Masahiro

Search repository
岩岡 和輝

× 岩岡 和輝

WEKO 549209

en 岩岡 和輝

Search repository
床次 眞司

× 床次 眞司

WEKO 549210

en 床次 眞司

Search repository
石川 徹夫

× 石川 徹夫

WEKO 549211

en 石川 徹夫

Search repository
小林 羊佐

× 小林 羊佐

WEKO 549212

en 小林 羊佐

Search repository
谷田部 慶憲

× 谷田部 慶憲

WEKO 549213

en 谷田部 慶憲

Search repository
米原 英典

× 米原 英典

WEKO 549214

en 米原 英典

Search repository
土居 雅広

× 土居 雅広

WEKO 549215

en 土居 雅広

Search repository
抄録
内容記述タイプ Abstract
内容記述 The deposition of radon decay products in each respiratory region can
increase the lung cancer risk. Therefore, it is necessary to calculate the
deposition of radon decay products in respiratory regions. Nowadays, the
deposition in each respiratory region is able to be imitated using wire
screens in many studies. Those studies employed grab sampling, that is,
sampling for short period less than several minutes. In natural environment,
because the concentration of radon decay products changes with time, it is
necessary to measure continuously. In this study continuous dosimeter (CD)
that imitates deposition of radon decay products in respiratory regions by
using wire screens was developed for the purpose of estimation of the
deposition in respiratory regions in various environments. The ratio of
activities deposited in the simulated N and TB regions was calculated from
results of measurement by CD-R, CD-N and CD-TB continuously, so that after
aerosols were injected into the radon chamber, the ratio of N and TB
depositions decreased, and, in addition, N / (N+TB) deposition decreased.
These results indicated that CD-R, CD-N and CD-TB could measure the change
of deposition ratio with time.
書誌情報 Proceedings of the Asian and Oceanic Congress for Radiation Protection

巻 4, p. 557-561, 発行日 2006-10
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 23:08:18.895404
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3