{"created":"2023-05-15T14:39:10.442705+00:00","id":53812,"links":{},"metadata":{"_buckets":{"deposit":"1a8741e9-67e0-49cd-99bb-8493ba73d05a"},"_deposit":{"created_by":1,"id":"53812","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"53812"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00053812","sets":["2"]},"author_link":["549208","549209","549210","549201","549204","549212","549211","549214","549205","549207","549213","549203","549206","549215","549202"],"item_10003_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2006-10","bibliographicIssueDateType":"Issued"},"bibliographicPageEnd":"561","bibliographicPageStart":"557","bibliographicVolumeNumber":"4","bibliographic_titles":[{"bibliographic_title":"Proceedings of the Asian and Oceanic Congress for Radiation Protection"}]}]},"item_10003_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"The deposition of radon decay products in each respiratory region can \nincrease the lung cancer risk. Therefore, it is necessary to calculate the \ndeposition of radon decay products in respiratory regions. Nowadays, the \ndeposition in each respiratory region is able to be imitated using wire \nscreens in many studies. Those studies employed grab sampling, that is, \nsampling for short period less than several minutes. In natural environment, \nbecause the concentration of radon decay products changes with time, it is \nnecessary to measure continuously. In this study continuous dosimeter (CD) \nthat imitates deposition of radon decay products in respiratory regions by \nusing wire screens was developed for the purpose of estimation of the \ndeposition in respiratory regions in various environments. The ratio of \nactivities deposited in the simulated N and TB regions was calculated from \nresults of measurement by CD-R, CD-N and CD-TB continuously, so that after \naerosols were injected into the radon chamber, the ratio of N and TB \ndepositions decreased, and, in addition, N / (N+TB) deposition decreased. \nThese results indicated that CD-R, CD-N and CD-TB could measure the change \nof deposition ratio with time.","subitem_description_type":"Abstract"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Iwaoka, Kazuki"}],"nameIdentifiers":[{"nameIdentifier":"549201","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Tokonami, Shinji"}],"nameIdentifiers":[{"nameIdentifier":"549202","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Ishikawa, Tetsuo"}],"nameIdentifiers":[{"nameIdentifier":"549203","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Kobayashi, Yosuke"}],"nameIdentifiers":[{"nameIdentifier":"549204","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Takahashi, Hiroyuki"}],"nameIdentifiers":[{"nameIdentifier":"549205","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Yatabe, Yoshinori"}],"nameIdentifiers":[{"nameIdentifier":"549206","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Yonehara, Hidenori"}],"nameIdentifiers":[{"nameIdentifier":"549207","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Doi, Masahiro"}],"nameIdentifiers":[{"nameIdentifier":"549208","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"岩岡 和輝","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"549209","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"床次 眞司","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"549210","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"石川 徹夫","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"549211","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"小林 羊佐","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"549212","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"谷田部 慶憲","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"549213","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"米原 英典","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"549214","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"土居 雅広","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"549215","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"conference paper","resourceuri":"http://purl.org/coar/resource_type/c_5794"}]},"item_title":"Development of Continuous Radon Bronchial Dosimeter","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Development of Continuous Radon Bronchial Dosimeter"}]},"item_type_id":"10003","owner":"1","path":["2"],"pubdate":{"attribute_name":"公開日","attribute_value":"2007-02-27"},"publish_date":"2007-02-27","publish_status":"0","recid":"53812","relation_version_is_last":true,"title":["Development of Continuous Radon Bronchial Dosimeter"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T23:08:18.790736+00:00"}