ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. プロシーディングス

The basic performance evaluation of the first model of 4 dimensional CT Scanner.

https://repo.qst.go.jp/records/53271
https://repo.qst.go.jp/records/53271
99dba48b-1b0a-4dfa-8516-61b26adbabbf
Item type 会議発表論文 / Conference Paper(1)
公開日 2003-12-19
タイトル
タイトル The basic performance evaluation of the first model of 4 dimensional CT Scanner.
言語
言語 jpn
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_5794
資源タイプ conference paper
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 森, 慎一郎

× 森, 慎一郎

WEKO 543697

森, 慎一郎

Search repository
遠藤, 真広

× 遠藤, 真広

WEKO 543698

遠藤, 真広

Search repository
角尾, 卓紀

× 角尾, 卓紀

WEKO 543699

角尾, 卓紀

Search repository
神立, 進

× 神立, 進

WEKO 543700

神立, 進

Search repository
棚田, 修二

× 棚田, 修二

WEKO 543701

棚田, 修二

Search repository
荒舘, 博

× 荒舘, 博

WEKO 543702

荒舘, 博

Search repository
斉藤, 泰男

× 斉藤, 泰男

WEKO 543703

斉藤, 泰男

Search repository
宮崎, 博明

× 宮崎, 博明

WEKO 543704

宮崎, 博明

Search repository
佐藤, 一雅

× 佐藤, 一雅

WEKO 543705

佐藤, 一雅

Search repository
松下, 聡

× 松下, 聡

WEKO 543706

松下, 聡

Search repository
日下部, 正宏

× 日下部, 正宏

WEKO 543707

日下部, 正宏

Search repository
森 慎一郎

× 森 慎一郎

WEKO 543708

en 森 慎一郎

Search repository
遠藤 真広

× 遠藤 真広

WEKO 543709

en 遠藤 真広

Search repository
角尾 卓紀

× 角尾 卓紀

WEKO 543710

en 角尾 卓紀

Search repository
神立 進

× 神立 進

WEKO 543711

en 神立 進

Search repository
棚田 修二

× 棚田 修二

WEKO 543712

en 棚田 修二

Search repository
佐藤 一雅

× 佐藤 一雅

WEKO 543713

en 佐藤 一雅

Search repository
松下 聡

× 松下 聡

WEKO 543714

en 松下 聡

Search repository
日下部 正宏

× 日下部 正宏

WEKO 543715

en 日下部 正宏

Search repository
抄録
内容記述タイプ Abstract
内容記述 This work was carried out to evaluate the basic performances for 4 dimensional computed tomography (4D-CT) scanner, which employs continuously rotating cone-beam. The performances were evaluated with the same method as the conventional CT, because the standard method of evaluating 4D-CT has not yet been established, and we think this result was helpful to establish it. 4D-CT scanner can give dynamic volume imaging data continuously and with high-speed. It uses a wide-area 2D detector designed on the basis of the present CT technology. The number of elements are 912(channels) x 256(segments), element size is approximately 1mm x 1mm, scanning time is 1sec, and data sampling rate is 900 views (frames)/sec. Feldkamp (FDK) algorithm was used for reconstruction. We measured six items as follows with stationary phantoms for 4D-CT, and compared them with the results of conventional multi-detector CT. 1.Noise, 2.Distortion, 3.Low Contrast and High Contrast resolution, 4.Spatial resolution, 5.Artifact, 6.Exposure dose measurement. The results were isotropic except for the evaluation of distortion in which small distortions gradually appeared as coming off the center of phantom in axial direction.
書誌情報 日本医学物理学会報文集

p. 000, 発行日 2003
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 23:14:32.042612
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3