{"created":"2023-05-15T14:38:43.691481+00:00","id":53271,"links":{},"metadata":{"_buckets":{"deposit":"d461fea7-2876-4c04-90f9-be0be1fe7930"},"_deposit":{"created_by":1,"id":"53271","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"53271"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00053271","sets":["2"]},"author_link":["543697","543703","543702","543710","543712","543714","543698","543704","543709","543711","543705","543707","543699","543706","543713","543715","543700","543708","543701"],"item_10003_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2003","bibliographicIssueDateType":"Issued"},"bibliographicPageStart":"000","bibliographic_titles":[{"bibliographic_title":"日本医学物理学会報文集"}]}]},"item_10003_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"This work was carried out to evaluate the basic performances for 4 dimensional computed tomography (4D-CT) scanner, which employs continuously rotating cone-beam. The performances were evaluated with the same method as the conventional CT, because the standard method of evaluating 4D-CT has not yet been established, and we think this result was helpful to establish it. 4D-CT scanner can give dynamic volume imaging data continuously and with high-speed. It uses a wide-area 2D detector designed on the basis of the present CT technology. The number of elements are 912(channels) x 256(segments), element size is approximately 1mm x 1mm, scanning time is 1sec, and data sampling rate is 900 views (frames)/sec. Feldkamp (FDK) algorithm was used for reconstruction. We measured six items as follows with stationary phantoms for 4D-CT, and compared them with the results of conventional multi-detector CT. 1.Noise, 2.Distortion, 3.Low Contrast and High Contrast resolution, 4.Spatial resolution, 5.Artifact, 6.Exposure dose measurement. The results were isotropic except for the evaluation of distortion in which small distortions gradually appeared as coming off the center of phantom in axial direction.","subitem_description_type":"Abstract"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"森, 慎一郎"}],"nameIdentifiers":[{"nameIdentifier":"543697","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"遠藤, 真広"}],"nameIdentifiers":[{"nameIdentifier":"543698","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"角尾, 卓紀"}],"nameIdentifiers":[{"nameIdentifier":"543699","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"神立, 進"}],"nameIdentifiers":[{"nameIdentifier":"543700","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"棚田, 修二"}],"nameIdentifiers":[{"nameIdentifier":"543701","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"荒舘, 博"}],"nameIdentifiers":[{"nameIdentifier":"543702","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"斉藤, 泰男"}],"nameIdentifiers":[{"nameIdentifier":"543703","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"宮崎, 博明"}],"nameIdentifiers":[{"nameIdentifier":"543704","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"佐藤, 一雅"}],"nameIdentifiers":[{"nameIdentifier":"543705","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"松下, 聡"}],"nameIdentifiers":[{"nameIdentifier":"543706","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"日下部, 正宏"}],"nameIdentifiers":[{"nameIdentifier":"543707","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"森 慎一郎","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"543708","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"遠藤 真広","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"543709","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"角尾 卓紀","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"543710","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"神立 進","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"543711","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"棚田 修二","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"543712","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"佐藤 一雅","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"543713","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"松下 聡","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"543714","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"日下部 正宏","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"543715","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"conference paper","resourceuri":"http://purl.org/coar/resource_type/c_5794"}]},"item_title":"The basic performance evaluation of the first model of 4 dimensional CT Scanner.","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"The basic performance evaluation of the first model of 4 dimensional CT Scanner."}]},"item_type_id":"10003","owner":"1","path":["2"],"pubdate":{"attribute_name":"公開日","attribute_value":"2003-12-19"},"publish_date":"2003-12-19","publish_status":"0","recid":"53271","relation_version_is_last":true,"title":["The basic performance evaluation of the first model of 4 dimensional CT Scanner."],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T23:14:31.934648+00:00"}