ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. プロシーディングス

Chromosome analysis in three patients.

https://repo.qst.go.jp/records/53255
https://repo.qst.go.jp/records/53255
b1d0718b-125d-4e19-b481-fff07923bee3
Item type 会議発表論文 / Conference Paper(1)
公開日 2003-11-18
タイトル
タイトル Chromosome analysis in three patients.
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_5794
資源タイプ conference paper
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Hayata, Isamu

× Hayata, Isamu

WEKO 543507

Hayata, Isamu

Search repository
Kanda, Reiko

× Kanda, Reiko

WEKO 543508

Kanda, Reiko

Search repository
Minamihisamatsu, Masako

× Minamihisamatsu, Masako

WEKO 543509

Minamihisamatsu, Masako

Search repository
Furukawa, Akira

× Furukawa, Akira

WEKO 543510

Furukawa, Akira

Search repository
Sasaki, Masao

× Sasaki, Masao

WEKO 543511

Sasaki, Masao

Search repository
早田 勇

× 早田 勇

WEKO 543512

en 早田 勇

Search repository
神田 玲子

× 神田 玲子

WEKO 543513

en 神田 玲子

Search repository
南久松 眞子

× 南久松 眞子

WEKO 543514

en 南久松 眞子

Search repository
古川 章

× 古川 章

WEKO 543515

en 古川 章

Search repository
佐々木 正夫

× 佐々木 正夫

WEKO 543516

en 佐々木 正夫

Search repository
抄録
内容記述タイプ Abstract
内容記述 Dose estimation for the 3 severely exposed cases was performed by chromosome analysis. The whole body dose of radiation they had been exposed to was an unprecedented much higher dose than we had encountered in previous radiation accidents. The rate of lymphocytes in the white blood cells in two of the cases was so low that we could not culture and harvest cells by the conventional method. We took two specific measures to break through this difficulty. First, to collect a sufficient number of lymphocytes necessary for chromosome preparation, we processed blood samples by a modified method called the high-yield chromosome preparation method. Secondly, the dose estimation was made by two methods: a new method of scoring the PCC-ring and an ordinary dicentric and ring chromosome (Dic+R) counting method. The quickly but crudely obtained result by the former was in good agreement with the result obtained by the more time-consuming but well established latter method. The biologically estimated dose was comparable with the dose estimated by the physical method. As far as we know, the estimated dose of the most severely exposed case in the present study is the highest known record to date of dose chromosome analyses could assess in human radiation exposures.
書誌情報 International Symposium on the Criticality Accident in Tokaimura : Medical Aspects of Radiation Emergency : Proceedings

p. 82-89, 発行日 2000
出版者
出版者 National Institute of Radiological Sciences
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 23:14:42.989931
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3