Dose Reconstruction for Heavily Exposed Patients of the Criticality Accident in Tokai-mura

https://repo.qst.go.jp/records/53120
https://repo.qst.go.jp/records/53120
41f0222e-2969-4698-8d01-2df8a2288606
Item type 会議発表論文 / Conference Paper(1)
公開日 2003-10-20
タイトル
タイトル Dose Reconstruction for Heavily Exposed Patients of the Criticality Accident in Tokai-mura
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_5794
資源タイプ conference paper
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Ishigure, Nobuhito

× Ishigure, Nobuhito

WEKO 541983

Ishigure, Nobuhito

Search repository
Endo, Akira

× Endo, Akira

WEKO 541984

Endo, Akira

Search repository
Yamaguchi, Yasuhiro

× Yamaguchi, Yasuhiro

WEKO 541985

Yamaguchi, Yasuhiro

Search repository
Kawachi, Kiyomitsu

× Kawachi, Kiyomitsu

WEKO 541986

Kawachi, Kiyomitsu

Search repository
石榑 信人

× 石榑 信人

WEKO 541987

en 石榑 信人

Search repository
遠藤 章

× 遠藤 章

WEKO 541988

en 遠藤 章

Search repository
山口 恭弘

× 山口 恭弘

WEKO 541989

en 山口 恭弘

Search repository
河内 清光

× 河内 清光

WEKO 541990

en 河内 清光

Search repository
抄録
内容記述タイプ Abstract
内容記述 A dose reconstruction for the heavily exposed patients is in progress using a numerical simulation technique where Monte Carlo simulation is applied under a calculation system that consists of the precipitation tank and two mathematical phantoms with movable arms and legs whose positions and postures are carefully modelled after those of patients A and B at the exposure. Tentative results show: (1) the average whole body neutron dose agreed well to that estimated by the measured specific activity of Na-24; (2) the average whole body gamma-ray dose was 2.4 times higher than the neutron dose for patient A and 1.9 times for patient B; (3) the highest dose at the skin of the abdomen for patient A was five times higher than the average whole body dose for neutrons and three times higher for gamma-rays; (4) the neutron dose in the body decreased markedly with a half value thickness of about 4 cm; (5) the contribution of neutron to the total dose reduced to 30% at 6 cm in depth, 25% at 10 cm and less than 10% at the back of the body.
書誌情報 International Symposium on the Criticality Accident in Tokaimura : Medical Aspects of Radiation Emergency : Proceedings

号 NIRS-M-146, p. 110-119, 発行日 2001-05
出版者
出版者 National Institute of Radiological Sciences
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 23:16:15.229723
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3