{"created":"2023-05-15T14:38:36.936471+00:00","id":53120,"links":{},"metadata":{"_buckets":{"deposit":"4adcb11d-e64e-4139-b812-2a2054f14378"},"_deposit":{"created_by":1,"id":"53120","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"53120"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00053120","sets":["2"]},"author_link":["541987","541985","541990","541984","541986","541983","541988","541989"],"item_10003_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2001-05","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"NIRS-M-146","bibliographicPageEnd":"119","bibliographicPageStart":"110","bibliographic_titles":[{"bibliographic_title":"International Symposium on the Criticality Accident in Tokaimura : Medical Aspects of Radiation Emergency : Proceedings"}]}]},"item_10003_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"A dose reconstruction for the heavily exposed patients is in progress using a numerical simulation technique where Monte Carlo simulation is applied under a calculation system that consists of the precipitation tank and two mathematical phantoms with movable arms and legs whose positions and postures are carefully modelled after those of patients A and B at the exposure. Tentative results show: (1) the average whole body neutron dose agreed well to that estimated by the measured specific activity of Na-24; (2) the average whole body gamma-ray dose was 2.4 times higher than the neutron dose for patient A and 1.9 times for patient B; (3) the highest dose at the skin of the abdomen for patient A was five times higher than the average whole body dose for neutrons and three times higher for gamma-rays; (4) the neutron dose in the body decreased markedly with a half value thickness of about 4 cm; (5) the contribution of neutron to the total dose reduced to 30% at 6 cm in depth, 25% at 10 cm and less than 10% at the back of the body.","subitem_description_type":"Abstract"}]},"item_10003_publisher_8":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"National Institute of Radiological Sciences"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Ishigure, Nobuhito"}],"nameIdentifiers":[{"nameIdentifier":"541983","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Endo, Akira"}],"nameIdentifiers":[{"nameIdentifier":"541984","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Yamaguchi, Yasuhiro"}],"nameIdentifiers":[{"nameIdentifier":"541985","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Kawachi, Kiyomitsu"}],"nameIdentifiers":[{"nameIdentifier":"541986","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"石榑 信人","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"541987","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"遠藤 章","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"541988","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"山口 恭弘","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"541989","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"河内 清光","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"541990","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"conference paper","resourceuri":"http://purl.org/coar/resource_type/c_5794"}]},"item_title":"Dose Reconstruction for Heavily Exposed Patients of the Criticality Accident in Tokai-mura","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Dose Reconstruction for Heavily Exposed Patients of the Criticality Accident in Tokai-mura"}]},"item_type_id":"10003","owner":"1","path":["2"],"pubdate":{"attribute_name":"公開日","attribute_value":"2003-10-20"},"publish_date":"2003-10-20","publish_status":"0","recid":"53120","relation_version_is_last":true,"title":["Dose Reconstruction for Heavily Exposed Patients of the Criticality Accident in Tokai-mura"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T23:16:15.128540+00:00"}