WEKO3
アイテム
{"_buckets": {"deposit": "705e0a57-9c24-40f3-9854-919c1a8ec47a"}, "_deposit": {"created_by": 1, "id": "53003", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "53003"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00053003", "sets": ["2"]}, "author_link": ["540637", "540638", "540636", "540639"], "item_10003_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2001-02", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "1", "bibliographicPageEnd": "77", "bibliographicPageStart": "75", "bibliographicVolumeNumber": "19", "bibliographic_titles": [{"bibliographic_title": "Journal of International Society of Life Information Science"}]}]}, "item_10003_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": " Delayed luminescence is a weak light in the visible spectrum region, which decays hyperbolically after exposure to external light illumination of the sample. It has a diagnostic value, although its fundamental properties are not well understood yet. We constructed a chopper system, which allows the illumination of the object with 100 Hz pulses of light. We collected the DL emission data on cooled CCD for 2D imaging between pulses\n", "subitem_description_type": "Abstract"}]}, "item_10003_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "1341-9226", "subitem_source_identifier_type": "ISSN"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Parkhomtchouk, Dmitri"}], "nameIdentifiers": [{"nameIdentifier": "540636", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Yamamoto, Mikio"}], "nameIdentifiers": [{"nameIdentifier": "540637", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "デミトリ パルホムチュク", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "540638", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "山本 幹男", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "540639", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "conference paper", "resourceuri": "http://purl.org/coar/resource_type/c_5794"}]}, "item_title": "2D Cooled CCD Imaging of Delayed Luminescence", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "2D Cooled CCD Imaging of Delayed Luminescence"}]}, "item_type_id": "10003", "owner": "1", "path": ["2"], "permalink_uri": "https://repo.qst.go.jp/records/53003", "pubdate": {"attribute_name": "公開日", "attribute_value": "2003-02-21"}, "publish_date": "2003-02-21", "publish_status": "0", "recid": "53003", "relation": {}, "relation_version_is_last": true, "title": ["2D Cooled CCD Imaging of Delayed Luminescence"], "weko_shared_id": -1}
2D Cooled CCD Imaging of Delayed Luminescence
https://repo.qst.go.jp/records/53003
https://repo.qst.go.jp/records/53003dbf39814-70d5-4cfb-b485-c4b21c7b834e
Item type | 会議発表論文 / Conference Paper(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2003-02-21 | |||||
タイトル | ||||||
タイトル | 2D Cooled CCD Imaging of Delayed Luminescence | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_5794 | |||||
資源タイプ | conference paper | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Parkhomtchouk, Dmitri
× Parkhomtchouk, Dmitri× Yamamoto, Mikio× デミトリ パルホムチュク× 山本 幹男 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Delayed luminescence is a weak light in the visible spectrum region, which decays hyperbolically after exposure to external light illumination of the sample. It has a diagnostic value, although its fundamental properties are not well understood yet. We constructed a chopper system, which allows the illumination of the object with 100 Hz pulses of light. We collected the DL emission data on cooled CCD for 2D imaging between pulses | |||||
書誌情報 |
Journal of International Society of Life Information Science 巻 19, 号 1, p. 75-77, 発行日 2001-02 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 1341-9226 |