{"created":"2023-05-15T14:38:31.800259+00:00","id":53003,"links":{},"metadata":{"_buckets":{"deposit":"705e0a57-9c24-40f3-9854-919c1a8ec47a"},"_deposit":{"created_by":1,"id":"53003","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"53003"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00053003","sets":["2"]},"author_link":["540637","540638","540636","540639"],"item_10003_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2001-02","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"1","bibliographicPageEnd":"77","bibliographicPageStart":"75","bibliographicVolumeNumber":"19","bibliographic_titles":[{"bibliographic_title":"Journal of International Society of Life Information Science"}]}]},"item_10003_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":" Delayed luminescence is a weak light in the visible spectrum region, which decays hyperbolically after exposure to external light illumination of the sample. It has a diagnostic value, although its fundamental properties are not well understood yet. We constructed a chopper system, which allows the illumination of the object with 100 Hz pulses of light. We collected the DL emission data on cooled CCD for 2D imaging between pulses\n","subitem_description_type":"Abstract"}]},"item_10003_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"1341-9226","subitem_source_identifier_type":"ISSN"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Parkhomtchouk, Dmitri"}],"nameIdentifiers":[{"nameIdentifier":"540636","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Yamamoto, Mikio"}],"nameIdentifiers":[{"nameIdentifier":"540637","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"デミトリ パルホムチュク","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"540638","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"山本 幹男","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"540639","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"conference paper","resourceuri":"http://purl.org/coar/resource_type/c_5794"}]},"item_title":"2D Cooled CCD Imaging of Delayed Luminescence","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"2D Cooled CCD Imaging of Delayed Luminescence"}]},"item_type_id":"10003","owner":"1","path":["2"],"pubdate":{"attribute_name":"公開日","attribute_value":"2003-02-21"},"publish_date":"2003-02-21","publish_status":"0","recid":"53003","relation_version_is_last":true,"title":["2D Cooled CCD Imaging of Delayed Luminescence"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T23:17:35.808011+00:00"}