64- and 128-pixel Si-APD linear array X-ray detectors with 0.5 ns time resolution

https://repo.qst.go.jp/records/49561
https://repo.qst.go.jp/records/49561
898cf40a-c451-4f55-aa24-5b1099dea887
Item type 学術雑誌論文 / Journal Article(1)
公開日 2019-02-06
タイトル
タイトル 64- and 128-pixel Si-APD linear array X-ray detectors with 0.5 ns time resolution
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Kishimoto, Shunji

× Kishimoto, Shunji

WEKO 873106

Kishimoto, Shunji

Search repository
三井, 隆也

× 三井, 隆也

WEKO 873107

三井, 隆也

Search repository
Haruki, Rie

× Haruki, Rie

WEKO 873108

Haruki, Rie

Search repository
Shimazaki, Shunichi

× Shimazaki, Shunichi

WEKO 873109

Shimazaki, Shunichi

Search repository
Tanaka, Masanobu

× Tanaka, Masanobu

WEKO 873110

Tanaka, Masanobu

Search repository
Mitsui, Takaya

× Mitsui, Takaya

WEKO 873111

en Mitsui, Takaya

Search repository
抄録
内容記述タイプ Abstract
内容記述 We developed a silicon avalanche photodiode (Si-APD) linear-array detector to be used for nuclear resonant scattering experiments using synchrotron X-rays. The detector has a 64-pixel or 128-pixel linear array (pixel size: 100 × 200 m 2 ). E ach xel tch s 1 0 m , and the depletion depth is 10 m he m lt channel scal ng (M S s stem for the detector counted X-ray pulses over 2048 continuous time bins with minimum time resolution of 0.5 ns. The detector system can record a time spectrum of the nuclear radiation simultaneously with an intensity distribution at each pixel. We
investigated its performance using synchrotron X-rays and the 128-pixel linear array exhibited a time resolution of 0.5 ns (full width at half maximum, FWHM) at 14.4 keV. A vacuum feedthrough for the 64-pixel linear array system was
fabricated to detect low-energy electrons of <10 keV using internal conversion electrons. The feedthrough consists of a fast-transmission flexible flat cable, multi-electrode micro connectors and a build-up printed circuit board. The energy
spectra of ~6 keV M-photoelectrons emitted from Tm foil were successively measured in vacuum with one pixel from the 64-pixel linear array using the vacuum feedthrough. The time spectrum was also recorded using the electron signal.
書誌情報 AIP Conference Proceedings

巻 2054, p. 060068-1-060068-6, 発行日 2019-01
出版者
出版者 AIP Publishing
DOI
識別子タイプ DOI
関連識別子 10.1063/1.5084699
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 18:06:12.344822
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3