{"created":"2023-05-15T14:38:23.932660+00:00","id":49561,"links":{},"metadata":{"_buckets":{"deposit":"f19ef348-4587-440b-a1bb-54ed4ea3bf24"},"_deposit":{"created_by":1,"id":"49561","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"49561"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00049561","sets":["1"]},"author_link":["873110","873106","873108","873109","873111","873107"],"item_8_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2019-01","bibliographicIssueDateType":"Issued"},"bibliographicPageEnd":"060068-6","bibliographicPageStart":"060068-1","bibliographicVolumeNumber":"2054","bibliographic_titles":[{"bibliographic_title":" AIP Conference Proceedings "}]}]},"item_8_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":" We developed a silicon avalanche photodiode (Si-APD) linear-array detector to be used for nuclear resonant scattering experiments using synchrotron X-rays. The detector has a 64-pixel or 128-pixel linear array (pixel size: 100 × 200 m 2 ). E ach xel tch s 1 0 m , and the depletion depth is 10 m he m lt channel scal ng (M S s stem for the detector counted X-ray pulses over 2048 continuous time bins with minimum time resolution of 0.5 ns. The detector system can record a time spectrum of the nuclear radiation simultaneously with an intensity distribution at each pixel. We \ninvestigated its performance using synchrotron X-rays and the 128-pixel linear array exhibited a time resolution of 0.5 ns (full width at half maximum, FWHM) at 14.4 keV. A vacuum feedthrough for the 64-pixel linear array system was \nfabricated to detect low-energy electrons of <10 keV using internal conversion electrons. The feedthrough consists of a fast-transmission flexible flat cable, multi-electrode micro connectors and a build-up printed circuit board. The energy \nspectra of ~6 keV M-photoelectrons emitted from Tm foil were successively measured in vacuum with one pixel from the 64-pixel linear array using the vacuum feedthrough. The time spectrum was also recorded using the electron signal.","subitem_description_type":"Abstract"}]},"item_8_publisher_8":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"AIP Publishing"}]},"item_8_relation_14":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_type_id":{"subitem_relation_type_id_text":"10.1063/1.5084699","subitem_relation_type_select":"DOI"}}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Kishimoto, Shunji"}],"nameIdentifiers":[{"nameIdentifier":"873106","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"三井, 隆也"}],"nameIdentifiers":[{"nameIdentifier":"873107","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Haruki, Rie"}],"nameIdentifiers":[{"nameIdentifier":"873108","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Shimazaki, Shunichi"}],"nameIdentifiers":[{"nameIdentifier":"873109","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Tanaka, Masanobu"}],"nameIdentifiers":[{"nameIdentifier":"873110","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Mitsui, Takaya","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"873111","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"64- and 128-pixel Si-APD linear array X-ray detectors with 0.5 ns time resolution","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"64- and 128-pixel Si-APD linear array X-ray detectors with 0.5 ns time resolution"}]},"item_type_id":"8","owner":"1","path":["1"],"pubdate":{"attribute_name":"公開日","attribute_value":"2019-02-06"},"publish_date":"2019-02-06","publish_status":"0","recid":"49561","relation_version_is_last":true,"title":["64- and 128-pixel Si-APD linear array X-ray detectors with 0.5 ns time resolution"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T21:49:53.365325+00:00"}