The design and thermo-structural analysis of target assembly for high intensity neutron source

https://repo.qst.go.jp/records/49554
https://repo.qst.go.jp/records/49554
13542ff2-7268-47d1-aff4-12a10b26150c
Item type 学術雑誌論文 / Journal Article(1)
公開日 2019-02-05
タイトル
タイトル The design and thermo-structural analysis of target assembly for high intensity neutron source
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Wakai, Eiichi

× Wakai, Eiichi

WEKO 759953

Wakai, Eiichi

Search repository
Watanabe, Kazuyoshi

× Watanabe, Kazuyoshi

WEKO 759954

Watanabe, Kazuyoshi

Search repository
近藤, 浩夫

× 近藤, 浩夫

WEKO 759955

近藤, 浩夫

Search repository
Groeschel, Friedrich

× Groeschel, Friedrich

WEKO 759956

Groeschel, Friedrich

Search repository
Kondo, Hiro

× Kondo, Hiro

WEKO 759957

en Kondo, Hiro

Search repository
抄録
内容記述タイプ Abstract
内容記述 The engineering design of an integrated target assembly of IFMIF lithium target was performed in IFMIF/EVEDA project for a high intensity neutron source. In the evaluation of the design, a thermos-structural analysis of was evaluated by ABAQUS code, and the modeling region was a part of the target assembly which was from the inlet nozzle to the outlet pipe. The material of the target assembly including the back plate was F82H steel. In the thermal-structural analysis, the normal operations and start/stop or abnormal operations were evaluated at 250 or 300°C operation of Li flow in inlet pipe. The result showed that the temperature of the target assembly was evaluated to be still lower than the Li boiling point of 344°C under a vacuum pressure of 10−3 Pa. In a temperature constant operation, the calculated stresses and displacements were small enough for thermal soundness of the target assembly in steady states. In a transient cooling process from 300 °C to 20°C through 250°C, the maximum Mises stress was found to be 372 MPa, which was lower than the yield stress at 300°C.
書誌情報 Nuclear Materials and Energy

巻 17, p. 15-23, 発行日 2018-07
出版者
出版者 Elsevier
ISSN
収録物識別子タイプ ISSN
収録物識別子 2352-1791
DOI
識別子タイプ DOI
関連識別子 10.1016/j.nme.2018.07.005
関連サイト
識別子タイプ URI
関連識別子 https://www.sciencedirect.com/science/article/pii/S2352179117301710
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 18:53:21.757733
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3