{"created":"2023-05-15T14:38:23.621918+00:00","id":49554,"links":{},"metadata":{"_buckets":{"deposit":"6cb29b5d-74e0-4989-8fa4-5d2842fea855"},"_deposit":{"created_by":1,"id":"49554","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"49554"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00049554","sets":["1"]},"author_link":["759956","759954","759957","759953","759955"],"item_8_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2018-07","bibliographicIssueDateType":"Issued"},"bibliographicPageEnd":"23","bibliographicPageStart":"15","bibliographicVolumeNumber":"17","bibliographic_titles":[{"bibliographic_title":"Nuclear Materials and Energy"}]}]},"item_8_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"The engineering design of an integrated target assembly of IFMIF lithium target was performed in IFMIF/EVEDA project for a high intensity neutron source. In the evaluation of the design, a thermos-structural analysis of was evaluated by ABAQUS code, and the modeling region was a part of the target assembly which was from the inlet nozzle to the outlet pipe. The material of the target assembly including the back plate was F82H steel. In the thermal-structural analysis, the normal operations and start/stop or abnormal operations were evaluated at 250 or 300°C operation of Li flow in inlet pipe. The result showed that the temperature of the target assembly was evaluated to be still lower than the Li boiling point of 344°C under a vacuum pressure of 10−3 Pa. In a temperature constant operation, the calculated stresses and displacements were small enough for thermal soundness of the target assembly in steady states. In a transient cooling process from 300 °C to 20°C through 250°C, the maximum Mises stress was found to be 372 MPa, which was lower than the yield stress at 300°C.","subitem_description_type":"Abstract"}]},"item_8_publisher_8":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"Elsevier"}]},"item_8_relation_14":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_type_id":{"subitem_relation_type_id_text":"10.1016/j.nme.2018.07.005","subitem_relation_type_select":"DOI"}}]},"item_8_relation_17":{"attribute_name":"関連サイト","attribute_value_mlt":[{"subitem_relation_type_id":{"subitem_relation_type_id_text":"https://www.sciencedirect.com/science/article/pii/S2352179117301710","subitem_relation_type_select":"URI"}}]},"item_8_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"2352-1791","subitem_source_identifier_type":"ISSN"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Wakai, Eiichi"}],"nameIdentifiers":[{"nameIdentifier":"759953","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Watanabe, Kazuyoshi"}],"nameIdentifiers":[{"nameIdentifier":"759954","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"近藤, 浩夫"}],"nameIdentifiers":[{"nameIdentifier":"759955","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Groeschel, Friedrich"}],"nameIdentifiers":[{"nameIdentifier":"759956","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Kondo, Hiro","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"759957","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"The design and thermo-structural analysis of target assembly for high intensity neutron source","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"The design and thermo-structural analysis of target assembly for high intensity neutron source"}]},"item_type_id":"8","owner":"1","path":["1"],"pubdate":{"attribute_name":"公開日","attribute_value":"2019-02-05"},"publish_date":"2019-02-05","publish_status":"0","recid":"49554","relation_version_is_last":true,"title":["The design and thermo-structural analysis of target assembly for high intensity neutron source"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-16T00:44:25.808613+00:00"}