ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 原著論文

Determination of the thermal and epithermal neutron sensitivities of an LBO chamber

https://repo.qst.go.jp/records/49014
https://repo.qst.go.jp/records/49014
e62e20a6-483f-4e1a-848f-84427bd63c20
Item type 学術雑誌論文 / Journal Article(1)
公開日 2018-05-15
タイトル
タイトル Determination of the thermal and epithermal neutron sensitivities of an LBO chamber
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 遠藤, 暁

× 遠藤, 暁

WEKO 494284

遠藤, 暁

Search repository
佐藤, 斉

× 佐藤, 斉

WEKO 494285

佐藤, 斉

Search repository
takuro, shimazaki

× takuro, shimazaki

WEKO 494286

takuro, shimazaki

Search repository
kotani, kei

× kotani, kei

WEKO 494287

kotani, kei

Search repository
須田, 充

× 須田, 充

WEKO 494288

須田, 充

Search repository
濱野, 毅

× 濱野, 毅

WEKO 494289

濱野, 毅

Search repository
梶本, 剛

× 梶本, 剛

WEKO 494290

梶本, 剛

Search repository
田中, 憲一

× 田中, 憲一

WEKO 494291

田中, 憲一

Search repository
星, 正治

× 星, 正治

WEKO 494292

星, 正治

Search repository
遠藤 暁

× 遠藤 暁

WEKO 494293

en 遠藤 暁

Search repository
佐藤 斉

× 佐藤 斉

WEKO 494294

en 佐藤 斉

Search repository
須田 充

× 須田 充

WEKO 494295

en 須田 充

Search repository
濱野 毅

× 濱野 毅

WEKO 494296

en 濱野 毅

Search repository
梶本 剛

× 梶本 剛

WEKO 494297

en 梶本 剛

Search repository
田中 憲一

× 田中 憲一

WEKO 494298

en 田中 憲一

Search repository
星 正治

× 星 正治

WEKO 494299

en 星 正治

Search repository
抄録
内容記述タイプ Abstract
内容記述 An LBO (Li2B4O7) walled ionization chamber
was designed to monitor the epithermal neutron fluence in
boron neutron capture therapy clinical irradiation. The
thermal and epithermal neutron sensitivities of the device
were evaluated using accelerator neutrons from the 9Be(d,
n) reaction at a deuteron energy of 4 MeV (4 MeV d-Be
neutrons). The response of the chamber in terms of the
electric charge induced in the LBO chamber was compared
with the thermal and epithermal neutron fluences measured
using the gold-foil activation method. The thermal and
epithermal neutron sensitivities obtained were expressed in
units of pC cm2, i.e., from the chamber response divided by
neutron fluence (cm-2). The measured LBO chamber
sensitivities were 2.23 9 10-7 ± 0.34 9 10-7 (pC cm2)
for thermal neutrons and 2.00 9 10-5 ± 0.12 9 10-5
(pC cm2) for epithermal neutrons. This shows that the LBO
chamber is sufficiently sensitive to epithermal neutrons to
be useful for epithermal neutron monitoring in BNCT
irradiation.
書誌情報 Radiat Environ Biophys

巻 56, 号 3, p. 269-276, 発行日 2017-07
ISSN
収録物識別子タイプ ISSN
収録物識別子 0301-634X
DOI
識別子タイプ DOI
関連識別子 10.1007/s00411-017-0700-y
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 23:21:54.370045
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3