MICRODOSIMETRIC APPLICATIONS IN PROTON AND HEAVY ION THERAPY USING SILICON MICRODOSIMETERS
https://repo.qst.go.jp/records/48973
https://repo.qst.go.jp/records/489730c727de3-f4a3-4b30-a75b-c300d72a9f97
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2018-03-19 | |||||
タイトル | ||||||
タイトル | MICRODOSIMETRIC APPLICATIONS IN PROTON AND HEAVY ION THERAPY USING SILICON MICRODOSIMETERS | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Lachlan, Chartier
× Lachlan, Chartier× Thuy Linh, Tran× David, BOLST× Guatelli, Susanna× Pogossov, A.× Anthony, Prokopovich× I. Reinhard, M.× Perevertaylo, V.× Anderson, S.× Beltran, C.× 松藤, 成弘× Jackson, M.× Rozenfeld, Anatoly× Lachlan, Chartier× Linh Tran, Thuy× BOLST, David× Prokopovich, Anthony× Matsufuji, Naruhiro× Anatoly, Rozenfeld |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Using the CMRP ‘bridge' μ+ probe, microdosimetric measurements were undertaken out-of-field using a therapeutic scanning proton pencil beam and in-field using a 12C ion therapy field. These measurements were undertaken at Mayo Clinic, Rochester, USA and at HIMAC, Chiba, Japan, respectively. For a typical proton field used in the treatment of deep-seated tumors, we observed dose-equivalent values ranging from 0.62 to 0.99 mSv/Gy at locations downstream of the distal edge. Lateral measurements at depths close to the entrance and along the SOBP plateau were found to reach maximum values of 3.1 mSv/Gy and 5.3 mSv/Gy at 10 mm from the field edge, respectively, and decreased to ~0.04 mSv/Gy 120 mm from the field edge. The ability to measure the dose-equivalent with high spatial resolution is particularly relevant to healthy tissue dose calculations in hadron therapy treatments. We have also shown qualitatively and quantitively the effects critical organ motion would have in treatment using microdosimetric spectra. Large differences in spectra and RBE10 were observed for treatments where miscalculations of 12C ion range would result in critical structures being irradiated, showing the importance of motion management. | |||||
書誌情報 |
Radiation Protection Dosimetry 巻 180, 号 1-4, p. 365-371, 発行日 2017-10 |
|||||
出版者 | ||||||
出版者 | Oxford University Press. | |||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0144-8420 | |||||
DOI | ||||||
識別子タイプ | DOI | |||||
関連識別子 | 10.1093/rpd/ncx226 | |||||
関連サイト | ||||||
識別子タイプ | URI | |||||
関連識別子 | https://academic.oup.com/rpd/article/180/1-4/365/4560563 |