ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 原著論文

Biomathematical screening of amyloid radiotracers with clinical usefulness index

https://repo.qst.go.jp/records/48960
https://repo.qst.go.jp/records/48960
f49946f3-754d-4bbd-a19c-3e3081284757
Item type 学術雑誌論文 / Journal Article(1)
公開日 2018-05-11
タイトル
タイトル Biomathematical screening of amyloid radiotracers with clinical usefulness index
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Nai, Ying-Hwey

× Nai, Ying-Hwey

WEKO 493472

Nai, Ying-Hwey

Search repository
Shidahara, Miho

× Shidahara, Miho

WEKO 493473

Shidahara, Miho

Search repository
Seki, Chie

× Seki, Chie

WEKO 493474

Seki, Chie

Search repository
Watabe, Hiroshi

× Watabe, Hiroshi

WEKO 493475

Watabe, Hiroshi

Search repository
志田原 美保

× 志田原 美保

WEKO 493476

en 志田原 美保

Search repository
関 千江

× 関 千江

WEKO 493477

en 関 千江

Search repository
渡部 浩司

× 渡部 浩司

WEKO 493478

en 渡部 浩司

Search repository
抄録
内容記述タイプ Abstract
内容記述 Introduction: To facilitate radiotracers’ development, a screening methodology using a biomathematical
model and clinical usefulness index (CUI) was proposed to evaluate radiotracers’ diagnostic
capabilities.
Methods: A total of 31 amyloid positron emission tomography radiotracers were evaluated. A previously
developed biomathematical model was used to simulate 1000 standardized uptake value
ratios with population and noise simulations, which were used to determine the integrated receiver
operating characteristics curve (Az), effect size (Es), and standardized uptake value ratio (Sr) of
conditions-pairs of healthy control–mild cognitive impaired and mild cognitive impaired–
Alzheimer’s disease. CUI was obtained from the product of averaged AzðAzÞ, EsðEsÞ, and SrðSrÞ.
Results: The relationships of Az, Es, and Sr with CUI were different, suggesting that they assessed
different radiotracer properties. The combination of Az, Es, and Sr complemented each other and resulted
in CUI of 0.10 to 5.72, with clinically applied amyloid positron emission tomography radiotracers
having CUI greater than 3.0.
Discussion: The CUI rankings of clinically applied radiotracers were close to their reported clinical
results, attesting to the applicability of the screening methodology.
書誌情報 Alzheimer’s & Dementia: Translational Research & Clinical Interventions

巻 3, 号 4, p. 542-552, 発行日 2017-09
PubMed番号
識別子タイプ PMID
関連識別子 29124113
DOI
識別子タイプ DOI
関連識別子 10.1016/j.trci.2017.08.006
関連サイト
識別子タイプ URI
関連識別子 https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5671631/
関連名称 https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5671631/
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 23:22:26.303042
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3