A New Approach for Quantifying Radio-Biological Effects using the Time Course of Mouse Leg Contracture

https://repo.qst.go.jp/records/48797
https://repo.qst.go.jp/records/48797
29bc6b25-5b6f-49af-82d0-6048b492301b
Item type 学術雑誌論文 / Journal Article(1)
公開日 2017-08-15
タイトル
タイトル A New Approach for Quantifying Radio-Biological Effects using the Time Course of Mouse Leg Contracture
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Ueno, Megumi

× Ueno, Megumi

WEKO 1024720

Ueno, Megumi

Search repository
Nakanishi, Ikuo

× Nakanishi, Ikuo

WEKO 1024721

Nakanishi, Ikuo

Search repository
Ken-ichiro, Matsumoto

× Ken-ichiro, Matsumoto

WEKO 1024722

Ken-ichiro, Matsumoto

Search repository
Megumi, Ueno

× Megumi, Ueno

WEKO 1024723

en Megumi, Ueno

Search repository
Ikuo, Nakanishi

× Ikuo, Nakanishi

WEKO 1024724

en Ikuo, Nakanishi

Search repository
Kenichiro, Matsumoto

× Kenichiro, Matsumoto

WEKO 1024725

en Kenichiro, Matsumoto

Search repository
抄録
内容記述タイプ Abstract
内容記述 A digitization approach to the time course of radiation-induced mouse leg contracture was proposed for quantifying the radiation effect on an individual living mouse. The shortening of the mouse leg length can be easily measured with a caliper/ruler to offer a very simple digitalized index of the radiation effect. Left hind legs of mice were irradiated with single dose of 32 Gy of 290 MeV carbon-ion beam using 0, 50, or 117 mm binary filter (BF). The right legs were used as a control. The lengths of both hind legs of the mice were measured using a digital caliper before irradiation and every week after irradiation. The degree of leg contracture, ΔSt, at the time point t was estimated by subtraction of the left irradiated leg length from the right control leg length. Equation 1 was fitted on the daily time course of ΔSt, and two parameters, ΔSmax and Ts, were estimated.
ΔSt = ΔSmax × ( 1 – exp(t / Ts) )[1]
where ΔSmax is the maximum degree of leg contracture, and Ts is time of leg contracture. The effect of carbon-ion irradiation on a living mouse was quantified by ΔSmax and Ts of the leg contracture, and then compared to that of X-rays. By 32 Gy irradiation, ΔSmax was largest for the BF117 experiment, followed by X-ray ~ BF50 > BF0. Ts was shortest for the BF50 experiment, while other irradiation conditions give similar Ts. A logarithmic function was successfully repurposed for the evaluation of radio-biological response.
書誌情報 Biological & Pharmaceutical Bulletin

巻 41, 号 3, p. 368-373, 発行日 2018-03
出版者
出版者 日本薬学会
ISSN
収録物識別子タイプ ISSN
収録物識別子 0918-6158
PubMed番号
識別子タイプ PMID
関連識別子 29491213
DOI
識別子タイプ DOI
関連識別子 10.1248/bpb.b17-00689
関連サイト
識別子タイプ URI
関連識別子 https://www.jstage.jst.go.jp/article/bpb/41/3/41_b17-00689/_article
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 17:05:30.198644
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3