ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 原著論文

Monitoring redox-sensitive paramagnetic contrast agent by EPRI, OMRI and MRI

https://repo.qst.go.jp/records/48490
https://repo.qst.go.jp/records/48490
2bdf1e18-be5d-4bd8-9516-ab5d9d80cddb
Item type 学術雑誌論文 / Journal Article(1)
公開日 2018-02-14
タイトル
タイトル Monitoring redox-sensitive paramagnetic contrast agent by EPRI, OMRI and MRI
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Hyodo, Fuminori

× Hyodo, Fuminori

WEKO 487490

Hyodo, Fuminori

Search repository
Murugesan, Ramachandran

× Murugesan, Ramachandran

WEKO 487491

Murugesan, Ramachandran

Search repository
Matsumoto, Ken-ichiro

× Matsumoto, Ken-ichiro

WEKO 487492

Matsumoto, Ken-ichiro

Search repository
Hyodo, Emi

× Hyodo, Emi

WEKO 487493

Hyodo, Emi

Search repository
Subramanian, Sankaran

× Subramanian, Sankaran

WEKO 487494

Subramanian, Sankaran

Search repository
B., Mitchell James

× B., Mitchell James

WEKO 487495

B., Mitchell James

Search repository
松本 謙一郎

× 松本 謙一郎

WEKO 487496

en 松本 謙一郎

Search repository
抄録
内容記述タイプ Abstract
内容記述 A comparative study of tissue redox-status imaging using commonly used redox sensitive nitroxides has been carried out using electron paramagnetic resonance imaging (EPRI), Overhauser magnetic resonance imaging (OMRI) and conventional T1-weighted magnetic resonance imaging, MRI. Imaging studies using phantoms of different nitroxides at different concentration levels showed that EPRI and OMRI sensitivities were found to be linearly dependent on line width of nitroxides up to 2 mM, and the enhancement in MRI intensity was linear up to 5 mM. The sensitivity and resolution of EPRI and OMRI images depended significantly on the line width of the nitroxides whereas the MRI images were almost independent of EPR line width.
Reduction of the paramagnetic 3-carbamoyl-2,2,5,5-tetramethylpyrrolidine-1-oxyl (3CP) by ascorbic acid (AsA) to the diamagnetic by hydroxylamine was monitored from a sequence of temporal images, acquired using the three imaging modalities. The decay rates determined by all the three modalities were found to be similar. However the results suggest that T1-weighted MRI can monitor the redox status, in addition to providing detailed anatomical structure in a short time. Therefore, a combination of MRI with nitroxides as metabolically responsive contrast agents can be a useful technique for the in vivo imaging probing tissue redox status.
書誌情報 Journal of Magnetic Resonance

巻 190, 号 1, p. 105-112, 発行日 2007-10
ISSN
収録物識別子タイプ ISSN
収録物識別子 1090-7807
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 23:27:30.199075
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3