ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 原著論文

Equivalency of the Quality of Sub-lethal Lesions after Photons and High-Linear Energy Transfer Ion Beams

https://repo.qst.go.jp/records/48455
https://repo.qst.go.jp/records/48455
062191ec-fa27-42ca-b720-5fc8d5bb717e
Item type 学術雑誌論文 / Journal Article(1)
公開日 2018-02-06
タイトル
タイトル Equivalency of the Quality of Sub-lethal Lesions after Photons and High-Linear Energy Transfer Ion Beams
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Furusawa, Yoshiya

× Furusawa, Yoshiya

WEKO 487170

Furusawa, Yoshiya

Search repository
Nakano-Aoki, Mizuho

× Nakano-Aoki, Mizuho

WEKO 487171

Nakano-Aoki, Mizuho

Search repository
Matsumoto, Yoshitaka

× Matsumoto, Yoshitaka

WEKO 487172

Matsumoto, Yoshitaka

Search repository
Hirayama, Ryoichi

× Hirayama, Ryoichi

WEKO 487173

Hirayama, Ryoichi

Search repository
Kobayashi, Alisa

× Kobayashi, Alisa

WEKO 487174

Kobayashi, Alisa

Search repository
Konishi, Teruaki

× Konishi, Teruaki

WEKO 487175

Konishi, Teruaki

Search repository
古澤 佳也

× 古澤 佳也

WEKO 487176

en 古澤 佳也

Search repository
青木 瑞穂

× 青木 瑞穂

WEKO 487177

en 青木 瑞穂

Search repository
松本 孔貴

× 松本 孔貴

WEKO 487178

en 松本 孔貴

Search repository
平山 亮一

× 平山 亮一

WEKO 487179

en 平山 亮一

Search repository
小林 亜利紗

× 小林 亜利紗

WEKO 487180

en 小林 亜利紗

Search repository
小西 輝昭

× 小西 輝昭

WEKO 487181

en 小西 輝昭

Search repository
抄録
内容記述タイプ Abstract
内容記述 To make the quality of the sublethal damage (SLD) after high-linear energy transfer (LET) ion beams was investigated with low-LET photons. Chinese hamster V79 cells and human squamous carcinoma SAS cells were first exposed to a priming dose of different ion beams at different LETs at the Heavy Ion Medical Accelerator in Chiba facility. The cells were kept at room temperature and then exposed to a secondary test dose of X-rays. Based on the repair kinetics study, the surviving fraction of cells quickly increased with the repair time, and reached a plateau in 2-3 h, even when cells had received priming monoenergetic high-LET beams or spread-out Bragg peak beams as well as X-ray. The shapes of the cell survival curves from the secondary test X-ray, after repair of the damage caused by the high-LET radiations, were similar to those obtained from cells exposed to primary X-ray only. Complete SLD repairs were observed even when the LET of the primary ion beams was very high. These results suggest that the SLD caused by high-LET radiations was repaired well, and likewise the damage caused by the X-ray. In cells where the ion beam had made a direct hit to the core region in an ion track, lethal damage to the domain was produced, resulting in cell death. On the other hand, in domains that had received a glancing hit at the low-LET penumbra region, the SLD produced was completely repaired.
書誌情報 Journal of Radiation Research

巻 58, 号 6, p. 803-808, 発行日 2017-06
出版者
出版者 Oxford University Press
ISSN
収録物識別子タイプ ISSN
収録物識別子 0449-3060
PubMed番号
識別子タイプ PMID
関連識別子 28992250
DOI
識別子タイプ DOI
関連識別子 10.1093/jrr/rrx030
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 23:27:53.863186
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3