{"_buckets": {"deposit": "d55006e0-4957-42e1-82c2-65015eda6f9c"}, "_deposit": {"created_by": 1, "id": "48425", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "48425"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00048425", "sets": ["1"]}, "author_link": ["486779", "486782", "486783", "486780", "486781", "486784"], "item_8_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2017-10", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "3", "bibliographicPageEnd": "95", "bibliographicPageStart": "89", "bibliographicVolumeNumber": "16", "bibliographic_titles": [{"bibliographic_title": "保全学"}]}]}, "item_8_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "本研究では、直径12 mm配管内の検査補修を行なうことを目的とし、2 つの圧電素子を直交して配置した定在波型超音波アクチュエータを 3 つ使用し、これを中空円板上に 120°間隔に並べてファイバースコープを通過させる空間を作り、直径12 mmの配管内で用いるレーザー加工ヘッドを開発したので、その構造や動作検証実験の結果について報告する。", "subitem_description_type": "Abstract"}]}, "item_8_publisher_8": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "日本保全学会"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "小松和三"}], "nameIdentifiers": [{"nameIdentifier": "486779", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "関健史"}], "nameIdentifiers": [{"nameIdentifier": "486780", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "長縄明大"}], "nameIdentifiers": [{"nameIdentifier": "486781", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "岡, 潔"}], "nameIdentifiers": [{"nameIdentifier": "486782", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "西村昭彦"}], "nameIdentifiers": [{"nameIdentifier": "486783", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "岡 潔", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "486784", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "1/2インチ配管内の検査補修用レーザー加工ヘッドの開発", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "1/2インチ配管内の検査補修用レーザー加工ヘッドの開発"}]}, "item_type_id": "8", "owner": "1", "path": ["1"], "permalink_uri": "https://repo.qst.go.jp/records/48425", "pubdate": {"attribute_name": "公開日", "attribute_value": "2018-01-11"}, "publish_date": "2018-01-11", "publish_status": "0", "recid": "48425", "relation": {}, "relation_version_is_last": true, "title": ["1/2インチ配管内の検査補修用レーザー加工ヘッドの開発"], "weko_shared_id": -1}
1/2インチ配管内の検査補修用レーザー加工ヘッドの開発
https://repo.qst.go.jp/records/48425
https://repo.qst.go.jp/records/48425782923b0-bbe8-48f5-9b41-26758a1050cc
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2018-01-11 | |||||
タイトル | ||||||
タイトル | 1/2インチ配管内の検査補修用レーザー加工ヘッドの開発 | |||||
言語 | ||||||
言語 | jpn | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
小松和三
× 小松和三× 関健史× 長縄明大× 岡, 潔× 西村昭彦× 岡 潔 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | 本研究では、直径12 mm配管内の検査補修を行なうことを目的とし、2 つの圧電素子を直交して配置した定在波型超音波アクチュエータを 3 つ使用し、これを中空円板上に 120°間隔に並べてファイバースコープを通過させる空間を作り、直径12 mmの配管内で用いるレーザー加工ヘッドを開発したので、その構造や動作検証実験の結果について報告する。 | |||||
書誌情報 |
保全学 巻 16, 号 3, p. 89-95, 発行日 2017-10 |
|||||