{"created":"2023-05-15T14:37:32.460495+00:00","id":48425,"links":{},"metadata":{"_buckets":{"deposit":"d55006e0-4957-42e1-82c2-65015eda6f9c"},"_deposit":{"created_by":1,"id":"48425","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"48425"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00048425","sets":["1"]},"author_link":["486779","486782","486783","486780","486781","486784"],"item_8_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2017-10","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"3","bibliographicPageEnd":"95","bibliographicPageStart":"89","bibliographicVolumeNumber":"16","bibliographic_titles":[{"bibliographic_title":"保全学"}]}]},"item_8_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"本研究では、直径12 mm配管内の検査補修を行なうことを目的とし、2 つの圧電素子を直交して配置した定在波型超音波アクチュエータを 3 つ使用し、これを中空円板上に 120°間隔に並べてファイバースコープを通過させる空間を作り、直径12 mmの配管内で用いるレーザー加工ヘッドを開発したので、その構造や動作検証実験の結果について報告する。","subitem_description_type":"Abstract"}]},"item_8_publisher_8":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"日本保全学会"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"小松和三"}],"nameIdentifiers":[{"nameIdentifier":"486779","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"関健史"}],"nameIdentifiers":[{"nameIdentifier":"486780","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"長縄明大"}],"nameIdentifiers":[{"nameIdentifier":"486781","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"岡, 潔"}],"nameIdentifiers":[{"nameIdentifier":"486782","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"西村昭彦"}],"nameIdentifiers":[{"nameIdentifier":"486783","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"岡 潔","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"486784","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"1/2インチ配管内の検査補修用レーザー加工ヘッドの開発","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"1/2インチ配管内の検査補修用レーザー加工ヘッドの開発"}]},"item_type_id":"8","owner":"1","path":["1"],"pubdate":{"attribute_name":"公開日","attribute_value":"2018-01-11"},"publish_date":"2018-01-11","publish_status":"0","recid":"48425","relation_version_is_last":true,"title":["1/2インチ配管内の検査補修用レーザー加工ヘッドの開発"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T23:28:15.202126+00:00"}