APPLICATION OF AN IMAGING PLATE FOR EVALUATING THE UNCERTAINTY IN DIRECT ORGAN MEASUREMENTS DUE TO VARIATION IN DETECTOR LOCATION

https://repo.qst.go.jp/records/48187
https://repo.qst.go.jp/records/48187
9c42616b-2601-4c02-9b8e-35e51c81363f
Item type 学術雑誌論文 / Journal Article(1)
公開日 2017-07-25
タイトル
タイトル APPLICATION OF AN IMAGING PLATE FOR EVALUATING THE UNCERTAINTY IN DIRECT ORGAN MEASUREMENTS DUE TO VARIATION IN DETECTOR LOCATION
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Kurihara, Osamu

× Kurihara, Osamu

WEKO 484031

Kurihara, Osamu

Search repository
Kanai, Katsuta

× Kanai, Katsuta

WEKO 484032

Kanai, Katsuta

Search repository
Hirota, Masahiro

× Hirota, Masahiro

WEKO 484033

Hirota, Masahiro

Search repository
Kim, Eunjoo

× Kim, Eunjoo

WEKO 484034

Kim, Eunjoo

Search repository
Kotaro, Tani

× Kotaro, Tani

WEKO 484035

Kotaro, Tani

Search repository
Takada, Chie

× Takada, Chie

WEKO 484036

Takada, Chie

Search repository
Momose, Takumaro

× Momose, Takumaro

WEKO 484037

Momose, Takumaro

Search repository
栗原 治

× 栗原 治

WEKO 484038

en 栗原 治

Search repository
金 ウンジュ

× 金 ウンジュ

WEKO 484039

en 金 ウンジュ

Search repository
谷 幸太郎

× 谷 幸太郎

WEKO 484040

en 谷 幸太郎

Search repository
抄録
内容記述タイプ Abstract
内容記述 In direct organ measurements, there can be uncertainty to the quantified amount of activity due to variations in detector locations.
Here, the authors demonstrate a new use of an imaging plate (IP) for evaluating this uncertainty. The method requires
only that an array of regions of interest (ROIs) is set on a latent image obtained from the IP; each ROI conforms to an active
area of the detector to be used. In this study, the proposed method was tested in an experiment using a realistic torso phantom
containing an 241Am liver source. The latent image of this source was obtained by irradiating the IP (20 × 40 cm2) from the
anterior surface of the phantom. A comparison of responses between the IP and a high-purity germanium detector was made
for 6 of the 144 circular ROIs arranged on the latent image, showing excellent correlation between the two sets of measures.
The dispersion of the photostimulated luminescence values of the 144 ROIs was found to be 8.2% (1σ) and 1.09 as a lognormal
scattering factor, which was expected to be the same as the uncertainty of concern in the present measurement with
the HPGe detector.
書誌情報 Radiation Protection Dosimetry

巻 170, 号 1/4, p. 252-255, 発行日 2016-09
出版者
出版者 Oxford Journals
DOI
識別子タイプ DOI
関連識別子 10.1093/rpd/ncw105
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 23:30:58.084867
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3