{"created":"2023-05-15T14:37:22.039013+00:00","id":48187,"links":{},"metadata":{"_buckets":{"deposit":"0f73514f-815d-4f7d-b18e-1512e9a3eaa8"},"_deposit":{"created_by":1,"id":"48187","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"48187"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00048187","sets":["1"]},"author_link":["484035","484033","484038","484039","484040","484031","484036","484032","484037","484034"],"item_8_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2016-09","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"1/4","bibliographicPageEnd":"255","bibliographicPageStart":"252","bibliographicVolumeNumber":"170","bibliographic_titles":[{"bibliographic_title":"Radiation Protection Dosimetry"}]}]},"item_8_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"In direct organ measurements, there can be uncertainty to the quantified amount of activity due to variations in detector locations.\nHere, the authors demonstrate a new use of an imaging plate (IP) for evaluating this uncertainty. The method requires\nonly that an array of regions of interest (ROIs) is set on a latent image obtained from the IP; each ROI conforms to an active\narea of the detector to be used. In this study, the proposed method was tested in an experiment using a realistic torso phantom\ncontaining an 241Am liver source. The latent image of this source was obtained by irradiating the IP (20 × 40 cm2) from the\nanterior surface of the phantom. A comparison of responses between the IP and a high-purity germanium detector was made\nfor 6 of the 144 circular ROIs arranged on the latent image, showing excellent correlation between the two sets of measures.\nThe dispersion of the photostimulated luminescence values of the 144 ROIs was found to be 8.2% (1σ) and 1.09 as a lognormal\nscattering factor, which was expected to be the same as the uncertainty of concern in the present measurement with\nthe HPGe detector.","subitem_description_type":"Abstract"}]},"item_8_publisher_8":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"Oxford Journals"}]},"item_8_relation_14":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_type_id":{"subitem_relation_type_id_text":"10.1093/rpd/ncw105","subitem_relation_type_select":"DOI"}}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Kurihara, Osamu"}],"nameIdentifiers":[{"nameIdentifier":"484031","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Kanai, Katsuta"}],"nameIdentifiers":[{"nameIdentifier":"484032","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Hirota, Masahiro"}],"nameIdentifiers":[{"nameIdentifier":"484033","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Kim, Eunjoo"}],"nameIdentifiers":[{"nameIdentifier":"484034","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Kotaro, Tani"}],"nameIdentifiers":[{"nameIdentifier":"484035","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Takada, Chie"}],"nameIdentifiers":[{"nameIdentifier":"484036","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Momose, Takumaro"}],"nameIdentifiers":[{"nameIdentifier":"484037","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"栗原 治","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"484038","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"金 ウンジュ","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"484039","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"谷 幸太郎","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"484040","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"APPLICATION OF AN IMAGING PLATE FOR EVALUATING THE UNCERTAINTY IN DIRECT ORGAN MEASUREMENTS DUE TO VARIATION IN DETECTOR LOCATION","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"APPLICATION OF AN IMAGING PLATE FOR EVALUATING THE UNCERTAINTY IN DIRECT ORGAN MEASUREMENTS DUE TO VARIATION IN DETECTOR LOCATION"}]},"item_type_id":"8","owner":"1","path":["1"],"pubdate":{"attribute_name":"公開日","attribute_value":"2017-07-25"},"publish_date":"2017-07-25","publish_status":"0","recid":"48187","relation_version_is_last":true,"title":["APPLICATION OF AN IMAGING PLATE FOR EVALUATING THE UNCERTAINTY IN DIRECT ORGAN MEASUREMENTS DUE TO VARIATION IN DETECTOR LOCATION"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T23:30:57.963408+00:00"}