WEKO3
-
RootNode
アイテム
An application of CCD read-out technique to neutron distribution measurement using the self-activation method with a CsI scintillator plate
https://repo.qst.go.jp/records/48117
https://repo.qst.go.jp/records/481175227c7a5-4669-4af9-b100-632002fbbddf
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2017-07-20 | |||||
タイトル | ||||||
タイトル | An application of CCD read-out technique to neutron distribution measurement using the self-activation method with a CsI scintillator plate | |||||
言語 | ||||||
言語 | jpn | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Nohtomi, Akihiro
× Nohtomi, Akihiro× Kurihara, Ryosuke× Kinoshita, Hiroyuki× Honda, Soichiro× Tokunaga, Masaaki× Uno, Heita× Shinsho, Kiyomitsu× Wakabayashi, Genichiro× 古場, 裕介× Fukunaga, Junichi× Umezu, Yoshiyuki× Nakamura, Yasuhiko× Ohga, Saiji× 古場 裕介 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | In our previous paper, the self-activation of an NaI scintillator had been successfully utilized for detecting photo-neutrons around a high-energy X-ray radiotherapy machine; individual optical pulses from the self-activated scintillator are read-out by photo sensors such as a photomultiplier tube (PMT). In the present work, preliminary observations have been performed in order to apply a direct CCD read-out technique to the self-activation method with a CsI scintillator plate using a Pu-Be source and a 10-MV linac. In conclusion, it has been revealed that the CCD read-out technique is applicable to neutron measurement around a high-energy X-ray radiotherapy machine with the self-activation of a CsI plate. Such application may provide a possibility of novel method for simple neutron dose-distribution measurement. | |||||
書誌情報 |
Nuclear Instruments and Methods in Physics Research A 巻 832, p. 21-23, 発行日 2016-06 |
|||||
出版者 | ||||||
出版者 | Elsevier | |||||
DOI | ||||||
識別子タイプ | DOI | |||||
関連識別子 | 10.1016/j.nima.2016.06.078 | |||||
関連サイト | ||||||
識別子タイプ | URI | |||||
関連識別子 | http://www.sciencedirect.com/science/article/pii/S0168900216306428 | |||||
関連名称 | http://www.sciencedirect.com/science/article/pii/S0168900216306428 |
Share
Cite as
Nohtomi, Akihiro, Kurihara, Ryosuke, Kinoshita, Hiroyuki, Honda, Soichiro, Tokunaga, Masaaki, Uno, Heita, Shinsho, Kiyomitsu, Wakabayashi, Genichiro, 古場, 裕介, Fukunaga, Junichi, Umezu, Yoshiyuki, Nakamura, Yasuhiko, Ohga, Saiji, 古場 裕介, 2016, An application of CCD read-out technique to neutron distribution measurement using the self-activation method with a CsI scintillator plate: Elsevier, 21–23 p.
Loading...