{"created":"2023-05-15T14:37:18.985814+00:00","id":48117,"links":{},"metadata":{"_buckets":{"deposit":"1318bf3a-d396-4c71-9d61-00ebb39d982a"},"_deposit":{"created_by":1,"id":"48117","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"48117"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00048117","sets":["1"]},"author_link":["483187","483191","483182","483178","483190","483184","483183","483185","483186","483179","483189","483188","483180","483181"],"item_8_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2016-06","bibliographicIssueDateType":"Issued"},"bibliographicPageEnd":"23","bibliographicPageStart":"21","bibliographicVolumeNumber":"832","bibliographic_titles":[{"bibliographic_title":"Nuclear Instruments and Methods in Physics Research A"}]}]},"item_8_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"In our previous paper, the self-activation of an NaI scintillator had been successfully utilized for detecting photo-neutrons around a high-energy X-ray radiotherapy machine; individual optical pulses from the self-activated scintillator are read-out by photo sensors such as a photomultiplier tube (PMT). In the present work, preliminary observations have been performed in order to apply a direct CCD read-out technique to the self-activation method with a CsI scintillator plate using a Pu-Be source and a 10-MV linac. In conclusion, it has been revealed that the CCD read-out technique is applicable to neutron measurement around a high-energy X-ray radiotherapy machine with the self-activation of a CsI plate. Such application may provide a possibility of novel method for simple neutron dose-distribution measurement.","subitem_description_type":"Abstract"}]},"item_8_publisher_8":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"Elsevier"}]},"item_8_relation_14":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_type_id":{"subitem_relation_type_id_text":"10.1016/j.nima.2016.06.078","subitem_relation_type_select":"DOI"}}]},"item_8_relation_17":{"attribute_name":"関連サイト","attribute_value_mlt":[{"subitem_relation_name":[{"subitem_relation_name_text":"http://www.sciencedirect.com/science/article/pii/S0168900216306428"}],"subitem_relation_type_id":{"subitem_relation_type_id_text":"http://www.sciencedirect.com/science/article/pii/S0168900216306428","subitem_relation_type_select":"URI"}}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Nohtomi, Akihiro"}],"nameIdentifiers":[{"nameIdentifier":"483178","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Kurihara, Ryosuke"}],"nameIdentifiers":[{"nameIdentifier":"483179","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Kinoshita, Hiroyuki"}],"nameIdentifiers":[{"nameIdentifier":"483180","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Honda, Soichiro"}],"nameIdentifiers":[{"nameIdentifier":"483181","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Tokunaga, Masaaki"}],"nameIdentifiers":[{"nameIdentifier":"483182","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Uno, Heita"}],"nameIdentifiers":[{"nameIdentifier":"483183","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Shinsho, Kiyomitsu"}],"nameIdentifiers":[{"nameIdentifier":"483184","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Wakabayashi, Genichiro"}],"nameIdentifiers":[{"nameIdentifier":"483185","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"古場, 裕介"}],"nameIdentifiers":[{"nameIdentifier":"483186","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Fukunaga, Junichi"}],"nameIdentifiers":[{"nameIdentifier":"483187","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Umezu, Yoshiyuki"}],"nameIdentifiers":[{"nameIdentifier":"483188","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Nakamura, Yasuhiko"}],"nameIdentifiers":[{"nameIdentifier":"483189","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Ohga, Saiji"}],"nameIdentifiers":[{"nameIdentifier":"483190","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"古場 裕介","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"483191","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"An application of CCD read-out technique to neutron distribution measurement using the self-activation method with a CsI scintillator plate","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"An application of CCD read-out technique to neutron distribution measurement using the self-activation method with a CsI scintillator plate"}]},"item_type_id":"8","owner":"1","path":["1"],"pubdate":{"attribute_name":"公開日","attribute_value":"2017-07-20"},"publish_date":"2017-07-20","publish_status":"0","recid":"48117","relation_version_is_last":true,"title":["An application of CCD read-out technique to neutron distribution measurement using the self-activation method with a CsI scintillator plate"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T23:31:46.413209+00:00"}