ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 原著論文

Carbon-ion pencil beam scanning for thoracic treatment - initiation report and dose metrics evaluation.

https://repo.qst.go.jp/records/47683
https://repo.qst.go.jp/records/47683
9c1d83a7-064f-4375-8507-857baaa1f67b
Item type 学術雑誌論文 / Journal Article(1)
公開日 2017-03-25
タイトル
タイトル Carbon-ion pencil beam scanning for thoracic treatment - initiation report and dose metrics evaluation.
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Karube, Masataka

× Karube, Masataka

WEKO 478444

Karube, Masataka

Search repository
Mori, Shinichiro

× Mori, Shinichiro

WEKO 478445

Mori, Shinichiro

Search repository
Tsuji, Hiroshi

× Tsuji, Hiroshi

WEKO 478446

Tsuji, Hiroshi

Search repository
Yamamoto, Naoyoshi

× Yamamoto, Naoyoshi

WEKO 478447

Yamamoto, Naoyoshi

Search repository
Nakajima, Mio

× Nakajima, Mio

WEKO 478448

Nakajima, Mio

Search repository
Nakagawa, Keiichi

× Nakagawa, Keiichi

WEKO 478449

Nakagawa, Keiichi

Search repository
Kamada, Tadashi

× Kamada, Tadashi

WEKO 478450

Kamada, Tadashi

Search repository
軽部 雅崇

× 軽部 雅崇

WEKO 478451

en 軽部 雅崇

Search repository
森 慎一郎

× 森 慎一郎

WEKO 478452

en 森 慎一郎

Search repository
辻 比呂志

× 辻 比呂志

WEKO 478453

en 辻 比呂志

Search repository
山本 直敬

× 山本 直敬

WEKO 478454

en 山本 直敬

Search repository
中嶋 美緒

× 中嶋 美緒

WEKO 478455

en 中嶋 美緒

Search repository
中川 恵一

× 中川 恵一

WEKO 478456

en 中川 恵一

Search repository
鎌田 正

× 鎌田 正

WEKO 478457

en 鎌田 正

Search repository
抄録
内容記述タイプ Abstract
内容記述 Carbon-ion beam scanning has not previously been used for moving tumor treatments. We have commenced respiratory-gated carbon-ion radiotherapy (CIRT) in the thoracic and abdominal regions under free-breathing conditions as a clinical trial. This study aimed to investigate this treatment in the lungs in comparison with passive scattering CIRT. Five patients had thoracic tumors treated with carbon-ion scanned beams using respiratory gating. We analyzed the actual treatments and calculated passive scattering treatment plans based on the same planning CT. We evaluated tumor size until 3 months post treatment and each treatment plan regarding dose delivered to 95% of the clinical target volume (CTV-D95), mean lung dose, percentage of lung receiving at least 5 Gy (RBE) (Lung-V5), Lung-V10, Lung-V20, heart maximum dose (Dmax), esophagus Dmax, cord Dmax and skin Dmax. Obvious tumor deterioration was not observed up to 3 months post treatment. The dose evaluation metrics were similar item by item between respiratory-gated scanned CIRT and passive scattering CIRT. In conclusion, scanned beam CIRT provided treatments equivalent to passive scattering CIRT for thoracic tumors. Increased sample numbers and longer-term observation are needed.
書誌情報 Journal of radiation research

巻 57, 号 5, p. 576-581, 発行日 2016-09
出版者
出版者 Oxford University Press
ISSN
収録物識別子タイプ ISSN
収録物識別子 0449-3060
PubMed番号
識別子タイプ PMID
関連識別子 27380799
DOI
識別子タイプ DOI
関連識別子 10.1093/jrr/rrw057
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 23:36:43.982403
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3