WEKO3
アイテム
DOSIS & DOSIS 3D: long-term dose monitoring onboard the Columbus Laboratory of the International Space Station (ISS)
https://repo.qst.go.jp/records/47590
https://repo.qst.go.jp/records/475907810bb51-981d-49a9-8428-b8096a20181d
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2016-12-08 | |||||
タイトル | ||||||
タイトル | DOSIS & DOSIS 3D: long-term dose monitoring onboard the Columbus Laboratory of the International Space Station (ISS) | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Berger, Thomas
× Berger, Thomas× Przybyla, Bartos× Matthia, Daniel× Reitz, Gunther× Burmeister, Sonke× Labrenz, Johannes× Bilski, Pawel× Horwacik, Tomasz× Twardak, Anna× Hajek, Michael× Fugger, Manfred× Hofstatter, Christina× Sihver, Lembit× K., Palfalvi Jozsef× Szabo, Julianna× Stradi, Andrea× Ambrozova, Iva× Kubancak, Jan× Pachnerova, Katerina× Vanhavere, Filip× Cauwels, Vanessa× Van, Hoey Olivier× Schoonjans, Werner× Parisi, Alessio× Gaza, Ramona× Semones, Edward× G., Yukihara Eduardo× Benton, Eric× A., Doull Brandon× Uchihori, Yukio× Kodaira, Satoshi× Kitamura, Hisashi× Boehme, Matthias× Berger Thomas× Przybyla Bartos× Reitz Gunther× Burmeister Sonke× Labrenz Johannes× Bilski Pawel× Hajek Michael× Sihver Lembit× イバ アンブロツォヴァ× Vangavere Filip× Semones Edward× Benton Eric× 内堀 幸夫× 小平 聡× 北村 尚 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | The radiation environment encountered in space differs in nature from that on Earth, consisting mostly of highly energetic ions from protons up to iron, resulting in radiation levels far exceeding the ones present on Earth for occupational radiation workers. Since the beginning of the space era, the radiation exposure during space missions has been monitored with various active and passive radiation instruments. Also onboard the International Space Station (ISS), a number of area monitoring devices provide data related to the spatial and temporal variation of the radiation field in and outside the ISS. The aim of the DOSIS (2009–2011) and the DOSIS 3D (2012–ongoing) experiments was and is to measure the radiation environment within the European Columbus Laboratory of the ISS. These measurements are, on the one hand, performed with passive radiation detectors mounted at 11 locations within Columbus for the determination of the spatial distribution of the radiation field parameters and, on the other, with two active radiation detectors mounted at a fixed position inside Columbus for the determination of the temporal variation of the radiation field parameters. Data measured with passive radiation detectors showed that the absorbed dose values inside the Columbus Laboratory follow a pattern, based on the local shielding configuration of the radiation detectors, with minimum dose values observed in the year 2010 of 195–270 μGy/day and maximum values observed in the year 2012 with values ranging from 260 to 360 μGy/day. The absorbed dose is modulated by (a) the variation in solar activity and (b) the changes in ISS altitude. | |||||
書誌情報 |
Journal of Space Weather and Space Climate 巻 6, 号 A39, p. 1-19, 発行日 2016-11 |
|||||
出版者 | ||||||
出版者 | SWSC | |||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 2115-7251 | |||||
DOI | ||||||
識別子タイプ | DOI | |||||
関連識別子 | 10.1051/swsc/2016036 | |||||
関連サイト | ||||||
識別子タイプ | URI | |||||
関連識別子 | http://www.swsc-journal.org/articles/swsc/full_html/2016/01/swsc160033/swsc160033.html | |||||
関連名称 | http://www.swsc-journal.org/articles/swsc/full_html/2016/01/swsc160033/swsc160033.html |